Submillimeter measurement of cup migration in clinical standard radiographs
- PMID: 15889554
- DOI: 10.1109/TMI.2005.846849
Submillimeter measurement of cup migration in clinical standard radiographs
Abstract
Assessing the displacement of bony implants is an important topic in arthroplasty, particularly in total hip replacement (THR). The observation of the migration is supposed to provide an insight into the fixation of the implant. Diagnostic standard radiographs of the pelvis are an advantageous data source for this purpose. The previous methods based on these images, however, lack of a thorough consideration of their projective nature. They do, hence, not reach the desired precision, which should lie in the submillimeter range to allow a detection of migration in the first one or two years after implantation. The aim of the work presented here was, therefore, a method for measuring the distance of the artificial hip socket to the bone with an error of less than 0.5 mm. The approach has been on the one hand to define the bone-cup distance measured in the radiograph so that the variability of the intrinsic and extrinsic parameters at exposure has a minimal impact. On the other, specialized matching techniques are applied in order to optimize the localization of the necessary bony landmarks and the cup in the X-ray image. The coordinates of the bony landmarks are determined by means of a template matching algorithm. The position of the implant is estimated by intensity-based registration using the cup's CAD-model. The method was validated theoretically, experimentally, and clinically. In the clinical radiographs, the standard deviation of the migration measurements resulted to be 0.28 mm when using only natural bony landmarks. The implantation of a bony marker was found to increase the precision to a standard deviation of 0.20 mm. The interobserver variability in the two cases was estimated to be 0.11 mm and 0.04 mm.
Similar articles
-
Measuring orthopedic implant wear on standard radiographs with a precision in the 10 microm-range.Med Image Anal. 2006 Aug;10(4):520-9. doi: 10.1016/j.media.2006.03.005. Epub 2006 Jul 26. Med Image Anal. 2006. PMID: 16872862
-
Radiographic stereometry for non-metal-backed acetubular cups: 3D wear estimation and related uncertainty.Med Image Anal. 2005 Jun;9(3):267-79. doi: 10.1016/j.media.2004.12.002. Epub 2005 Jan 19. Med Image Anal. 2005. PMID: 15854846
-
2D/3D registration for measurement of implant alignment after total hip replacement.Med Image Comput Comput Assist Interv. 2006;9(Pt 2):653-61. doi: 10.1007/11866763_80. Med Image Comput Comput Assist Interv. 2006. PMID: 17354828 Clinical Trial.
-
New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters.Acta Orthop Suppl. 2005 Feb;76(315):3-82. Acta Orthop Suppl. 2005. PMID: 15790289 Review.
-
Dual mobility in total hip arthroplasty.Orthop Clin North Am. 2014 Jan;45(1):1-8. doi: 10.1016/j.ocl.2013.08.004. Epub 2013 Oct 1. Orthop Clin North Am. 2014. PMID: 24267202 Review.
Cited by
-
A moving fluoroscope to capture tibiofemoral kinematics during complete cycles of free level and downhill walking as well as stair descent.PLoS One. 2017 Oct 9;12(10):e0185952. doi: 10.1371/journal.pone.0185952. eCollection 2017. PLoS One. 2017. PMID: 29016647 Free PMC article.
-
Elongation Patterns of the Posterior Cruciate Ligament after Total Knee Arthroplasty.J Clin Med. 2020 Jul 2;9(7):2078. doi: 10.3390/jcm9072078. J Clin Med. 2020. PMID: 32630654 Free PMC article.
-
Techniques for In Vivo Measurement of Ligament and Tendon Strain: A Review.Ann Biomed Eng. 2021 Jan;49(1):7-28. doi: 10.1007/s10439-020-02635-5. Epub 2020 Oct 6. Ann Biomed Eng. 2021. PMID: 33025317 Free PMC article. Review.
-
Elongation Patterns of the Collateral Ligaments After Total Knee Arthroplasty Are Dominated by the Knee Flexion Angle.Front Bioeng Biotechnol. 2019 Nov 12;7:323. doi: 10.3389/fbioe.2019.00323. eCollection 2019. Front Bioeng Biotechnol. 2019. PMID: 31799245 Free PMC article.
-
Knee implant kinematics are task-dependent.J R Soc Interface. 2019 Feb 28;16(151):20180678. doi: 10.1098/rsif.2018.0678. J R Soc Interface. 2019. PMID: 30958178 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous