Inflammatory Cytokine Inhibition of Erythropoiesis in Patients Implanted With a Mechanical Circulatory Assist Device

Affiliations
Comparative Study

Inflammatory Cytokine Inhibition of Erythropoiesis in Patients Implanted With a Mechanical Circulatory Assist Device

Christopher N Pierce et al. Perfusion.

Erratum in

  • Perfusion. 2005 May;20(3):183

Abstract

Mechanical circulatory assist devices (MCADs) are increasingly utilized independently of cardiac transplantation in the management of heart failure. Though MCAD use incorporates inherent mechanical risks, the inevitable onset of chronic anemia, with its associated morbidity and mortality, is also a significant concern. MCAD support has been correlated with elevated plasma levels of inflammatory cytokines TNF-alpha, IL-1beta, and IL-6, which have separately been found to inhibit erythropoietin (Epo)-induced erythrocyte (RBC) maturation. Previous analysis of hematological parameters for MCAD-supported patients concluded that an amplified inflammatory response impedes RBC proliferation and recovery from hemolytic anemia. Additional analysis may bolster this assertion. Hemoglobin concentration (HC), RBC distribution width (RDW), mean cell volume (MCV), and cardiac index were retrospectively analysed for 78 MCAD-supported patients implanted for greater than 30 days at the University of Arizona Health Sciences Center from 1996 to 2002. Analysis confirms that the HC, a conventional marker for anemia, declines with MCAD placement and remains below the clinically defined, minimum normal value. Inversely, the RDW rises above maximum normal measure, signifying an increased fraction of juvenile RBCs. The MCV remains unchanged and within normal limits, demonstrating adequate substrate for RBC formation. MCAD performance also stabilizes as adequate perfusion returns. These results further support our previously published conclusion that a sufficient response of erythropoiesis occurs in reaction to the onset of anemia by an increased production of immature RBCs. However, the cells never fully mature and join circulation. The patient's inflammatory cytokine response to the implanted device most likely mediates the chronic MCAD-induced anemia by inhibition of Epo effects.

Similar articles

See all similar articles

Cited by 57 PubMed Central articles

See all "Cited by" articles

Publication types

Feedback