A comparison of the PROCAM and Framingham point-scoring systems for estimation of individual risk of coronary heart disease in the Second Northwick Park Heart Study

Atherosclerosis. 2005 Jul;181(1):93-100. doi: 10.1016/j.atherosclerosis.2004.12.026.

Abstract

We have compared the predictive value of the PROCAM and Framingham risk algorithms in healthy UK men from the Second Northwick Park Heart Study (NPHS-II) (50-64 years at entry), followed for a median of 10.8 years for coronary heart disease (CHD) events. For PROCAM, the area under the receiver operating characteristic (ROC) curve was 0.63 (95% CI, 0.59-0.67), and not significantly different (p = 0.46) from the Framingham score, 0.62 (0.58-0.66). Sensitivities for a 5% false-positive rate (DR(5)) were 13.8 and 12.4%, respectively. Calibration analysis for PROCAM gave a ratio of observed to expected events of 0.46 (Hosmer-Lemeshow test, p < 0.0001) and 0.47 for Framingham (p < 0.0001). Using measures taken at 5 years of high-density lipoprotein cholesterol and (estimated) low-density lipoprotein cholesterol levels increased the ROC by only 1%. An NPHS-II risk algorithm, developed using a 50% random subset, and including age, triglyceride, total cholesterol, smoking status, and systolic blood pressure at recruitment, gave an ROC of 0.64 (0.58-0.70) with a DR(5) of 10.7% when applied to the second half of the data. Adding family history and diabetes increased the DR(5) to 18.4% (p = 0.28). Adding lipoprotein(a) >26.3 mg/dL (relative risk 1.6, 1.1-2.4) gave a DR(5) of 15.5% (p = 0.55), while adding fibrinogen levels (relative risk for 1S.D. increase = 1.5, 1.1-2.0) had essentially no additional impact (DR(5) = 16.9%, p = 0.95). Thus, the PROCAM algorithm is marginally better as a risk predictor in UK men than the Framingham score, but both significantly overestimate risk in UK men. The algorithm based on NPHS-II data performs similarly to those for PROCAM and Framingham with respect to discrimination, but gave an improved ratio of observed to expected events of 0.80 (p = 0.01), although no score had a high sensitivity. Any novel factors added to these algorithms will need to have a major impact on risk to increase sensitivity above that given by classical risk factors.

Publication types

  • Comparative Study
  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't
  • Research Support, U.S. Gov't, P.H.S.

MeSH terms

  • Algorithms
  • Calibration
  • Cholesterol, HDL / blood
  • Cholesterol, LDL / blood
  • Coronary Disease / etiology*
  • Diabetes Complications
  • Fibrinogen / metabolism
  • Humans
  • Male
  • Medical Records
  • Middle Aged
  • Predictive Value of Tests
  • ROC Curve
  • Risk Assessment / methods

Substances

  • Cholesterol, HDL
  • Cholesterol, LDL
  • Fibrinogen