Case report: a novel solution to penile zipper injury--the needle holder

ScientificWorldJournal. 2005 Apr 6:5:298-9. doi: 10.1100/tsw.2005.39.

Abstract

Penile injuries are relatively uncommon. The crush injury mediated by entrapment of the skin between the teeth and fastener of a zipper mechanism has been described. It is seen more commonly in uncircumcised children than adults. A number of treatment methods have been mentioned in the literature. An adult case presentation and novel method of management using two small needle holders is illustrated.

Publication types

  • Case Reports

MeSH terms

  • Adult
  • Clothing
  • Humans
  • Male
  • Needles
  • Penis / injuries*
  • Suture Techniques / instrumentation