A programmable microsystem using system-on-chip for real-time biotelemetry
- PMID: 16041988
- DOI: 10.1109/TBME.2005.847562
A programmable microsystem using system-on-chip for real-time biotelemetry
Abstract
A telemetry microsystem, including multiple sensors, integrated instrumentation and a wireless interface has been implemented. We have employed a methodology akin to that for System-on-Chip microelectronics to design an integrated circuit instrument containing several "intellectual property" blocks that will enable convenient reuse of modules in future projects. The present system was optimized for low-power and included mixed-signal sensor circuits, a programmable digital system, a feedback clock control loop and RF circuits integrated on a 5 mm x 5 mm silicon chip using a 0.6 microm, 3.3 V CMOS process. Undesirable signal coupling between circuit components has been investigated and current injection into sensitive instrumentation nodes was minimized by careful floor-planning. The chip, the sensors, a magnetic induction-based transmitter and two silver oxide cells were packaged into a 36 mm x 12 mm capsule format. A base station was built in order to retrieve the data from the microsystem in real-time. The base station was designed to be adaptive and timing tolerant since the microsystem design was simplified to reduce power consumption and size. The telemetry system was found to have a packet error rate of 10(-3) using an asynchronous simplex link. Trials in animal carcasses were carried out to show that the transmitter was as effective as a conventional RF device whilst consuming less power.
Similar articles
-
A system-on-chip digital pH meter for use in a wireless diagnostic capsule.IEEE Trans Biomed Eng. 2005 Apr;52(4):687-94. doi: 10.1109/TBME.2005.844041. IEEE Trans Biomed Eng. 2005. PMID: 15825870
-
Low-power transceiver analog front-end circuits for bidirectional high data rate wireless telemetry in medical endoscopy applications.IEEE Trans Biomed Eng. 2007 Jul;54(7):1291-9. doi: 10.1109/TBME.2006.889768. IEEE Trans Biomed Eng. 2007. PMID: 17605360
-
Implementation of multichannel sensors for remote biomedical measurements in a microsystems format.IEEE Trans Biomed Eng. 2004 Mar;51(3):525-35. doi: 10.1109/TBME.2003.820370. IEEE Trans Biomed Eng. 2004. PMID: 15000383
-
Wireless technologies for closed-loop retinal prostheses.J Neural Eng. 2009 Dec;6(6):065004. doi: 10.1088/1741-2560/6/6/065004. Epub 2009 Oct 23. J Neural Eng. 2009. PMID: 19850974 Review.
-
Principles of development and design of microsystems.Endosc Surg Allied Technol. 1995 Aug;3(4):204-9. Endosc Surg Allied Technol. 1995. PMID: 8846038 Review.
Cited by
-
Low-power wireless electronic capsule for long-term gastrointestinal monitoring.J Med Syst. 2015 Feb;39(2):9. doi: 10.1007/s10916-015-0211-9. Epub 2015 Jan 29. J Med Syst. 2015. PMID: 25631843
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources

