Abstract
Objectives: The aim of our study was to evaluate the diagnostic accuracy of multislice computed tomography (MSCT) coronary angiography using a new 64-slice scanner.
Background: The new 64-slice MSCT scanner has improved spatial resolution of 0.4 mm and a faster rotation time (330 ms) compared to prior MSCT scanners.
Methods: We studied 70 consecutive patients undergoing elective invasive coronary angiography. Patients were excluded for atrial fibrillation, but not for high heart rate, coronary calcification, or obesity. All vessels were analyzed, including those <1.5 mm in diameter; MSCT lesions were analyzed quantitatively as well as by a qualitative scale and compared to quantitative coronary angiography (QCA). Results were also analyzed for significant coronary stenoses (over 50% luminal narrowing) by segment, by artery, and by patient.
Results: All scans showed diagnostic image quality. Of 1,065 segments, 935 (88%) could be evaluated, and 773 of 935 (83%) could be assessed quantitatively by both MSCT and QCA. The Spearman correlation coefficient between MSCT and QCA was 0.76 (p < 0.0001). Bland-Altman analysis demonstrated a mean difference in percent stenosis of 1.3 +/- 14.2%. A total of 26% of patients had calcium scores above 400 Agatston U, 25% had heart rates >70 beats/min, and 50% were obese. Specificity, sensitivity, and positive and negative predictive values for the presence of significant stenoses were: by segment (n = 935), 86%, 95%, 66%, and 98%, respectively; by artery (n = 279), 91%, 92%, 80%, and 97%, respectively; by patient (n = 70), 95%, 90%, 93%, and 93%, respectively.
Conclusions: Our results indicate high quantitative and qualitative diagnostic accuracy of 64-slice MSCT in comparison to QCA in a broad spectrum of patients.
Comment in
-
Accuracy of noninvasive coronary angiography using computed tomography.J Am Coll Cardiol. 2006 Jul 4;48(1):219; author reply 219. doi: 10.1016/j.jacc.2006.04.003. Epub 2006 Jun 9. J Am Coll Cardiol. 2006. PMID: 16814674 No abstract available.
Similar articles
-
Heart imaging: the accuracy of the 64-MSCT in the detection of coronary artery disease.Eur Rev Med Pharmacol Sci. 2009 May-Jun;13(3):163-71. Eur Rev Med Pharmacol Sci. 2009. PMID: 19673166
-
Noninvasive coronary angiography with multislice computed tomography.JAMA. 2005 May 25;293(20):2471-8. doi: 10.1001/jama.293.20.2471. JAMA. 2005. PMID: 15914747
-
Image quality and diagnostic accuracy of 16-slice multidetector computed tomography for the detection of coronary artery disease in obese patients.Int J Obes (Lond). 2006 Mar;30(3):569-73. doi: 10.1038/sj.ijo.0803157. Int J Obes (Lond). 2006. PMID: 16276363
-
Diagnostic value of multislice computed tomography angiography in coronary artery disease: a meta-analysis.Eur J Radiol. 2006 Nov;60(2):279-86. doi: 10.1016/j.ejrad.2006.06.009. Epub 2006 Aug 2. Eur J Radiol. 2006. PMID: 16887313 Review.
-
Accuracy of multislice computed tomography coronary angiography: a pooled estimate.Cardiol Rev. 2008 Jul-Aug;16(4):189-96. doi: 10.1097/CRD.0b013e318164d02a. Cardiol Rev. 2008. PMID: 18562809 Review.
Cited by
-
Calcific versus non-calcific plaque: a CAD-RADS and FFRCT study.Int J Cardiovasc Imaging. 2024 Nov 21. doi: 10.1007/s10554-024-03281-x. Online ahead of print. Int J Cardiovasc Imaging. 2024. PMID: 39572503
-
Comparison of coronary CT angiography and invasive coronary angiography results.Ir J Med Sci. 2024 Oct;193(5):2239-2248. doi: 10.1007/s11845-024-03745-y. Epub 2024 Jul 4. Ir J Med Sci. 2024. PMID: 38965116 Free PMC article.
-
Super resolution deep learning reconstruction for coronary CT angiography: A structured phantom study.Eur J Radiol Open. 2024 May 24;12:100570. doi: 10.1016/j.ejro.2024.100570. eCollection 2024 Jun. Eur J Radiol Open. 2024. PMID: 38828096 Free PMC article.
-
Positive Predictive Value of Computerized Tomography Coronary Angiography versus Computerized Tomography Fractional Flow Reserve in a Real-world Population.Heart Views. 2024 Jan-Mar;25(1):2-8. doi: 10.4103/heartviews.heartviews_82_23. Epub 2024 Apr 12. Heart Views. 2024. PMID: 38774553 Free PMC article.
-
Evaluation of four computed tomography reconstruction algorithms using a coronary artery phantom.Quant Imaging Med Surg. 2024 Apr 3;14(4):2870-2883. doi: 10.21037/qims-23-1204. Epub 2024 Mar 27. Quant Imaging Med Surg. 2024. PMID: 38617144 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical