Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial
- PMID: 16084255
- DOI: 10.1016/S0140-6736(05)67061-4
Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial
Abstract
Background: Over the past 30 years the pulmonary artery catheter (PAC) has become a widely used haemodynamic monitoring device in the management of critically ill patients, though doubts exist about its safety. Our aim was, therefore, to ascertain whether hospital mortality is reduced in critically ill patients when they are managed with a PAC.
Methods: We did a randomised controlled trial to which we enrolled 1041 patients from 65 UK intensive care units. We assigned individuals to management with (n=519) or without (n=522) a PAC. The timing of insertion and subsequent clinical management were at the discretion of the treating clinician. Intensive care units decided a priori to have the option of using an alternative cardiac output-monitoring device in control patients.
Findings: 1014 patients were eligible for analysis. We noted no difference in hospital mortality between patients managed with or without a PAC (68% [346 of 506] vs 66% [333 of 507], p=0.39; adjusted hazard ratio 1.09, 95% CI 0.94-1.27). We noted complications associated with insertion of a PAC in 46 of 486 individuals in whom the device was placed, none of which was fatal.
Interpretation: Our findings indicate no clear evidence of benefit or harm by managing critically ill patients with a PAC. Efficacy studies are needed to ascertain whether management protocols involving PAC use can result in improved outcomes in specific groups if these devices are not to become a redundant technology.
Comment in
-
Pulmonary artery catheters in intensive care.Lancet. 2005 Aug 6-12;366(9484):435-6. doi: 10.1016/S0140-6736(05)67038-9. Lancet. 2005. PMID: 16084236 No abstract available.
-
Management with a pulmonary artery catheter did not reduce all-cause mortality in critically ill patients.ACP J Club. 2006 Jan-Feb;144(1):21. ACP J Club. 2006. PMID: 16388570 No abstract available.
-
Management of critically ill patients with a pulmonary artery catheter did not reduce all cause mortality.Evid Based Nurs. 2006 Apr;9(2):53. doi: 10.1136/ebn.9.2.53. Evid Based Nurs. 2006. PMID: 16622930 No abstract available.
Similar articles
-
An evaluation of the clinical and cost-effectiveness of pulmonary artery catheters in patient management in intensive care: a systematic review and a randomised controlled trial.Health Technol Assess. 2006 Aug;10(29):iii-iv, ix-xi, 1-133. doi: 10.3310/hta10290. Health Technol Assess. 2006. PMID: 16904048 Review.
-
Pulmonary artery catheters for adult patients in intensive care.Cochrane Database Syst Rev. 2013 Feb 28;2013(2):CD003408. doi: 10.1002/14651858.CD003408.pub3. Cochrane Database Syst Rev. 2013. PMID: 23450539 Free PMC article. Review.
-
Post hoc insights from PAC-Man--the U.K. pulmonary artery catheter trial.Crit Care Med. 2008 Jun;36(6):1714-21. doi: 10.1097/CCM.0b013e318174315d. Crit Care Med. 2008. PMID: 18496358 Clinical Trial.
-
Pulmonary artery catheters for adult patients in intensive care.Cochrane Database Syst Rev. 2006 Jul 19;(3):CD003408. doi: 10.1002/14651858.CD003408.pub2. Cochrane Database Syst Rev. 2006. Update in: Cochrane Database Syst Rev. 2013 Feb 28;(2):CD003408. doi: 10.1002/14651858.CD003408.pub3 PMID: 16856008 Updated. Review.
-
A randomised, controlled trial of the pulmonary artery catheter in critically ill patients.Intensive Care Med. 2002 Mar;28(3):256-64. doi: 10.1007/s00134-002-1206-9. Epub 2002 Feb 13. Intensive Care Med. 2002. PMID: 11904653 Clinical Trial.
Cited by
-
Capnodynamic assessment of mixed venous oxygen saturation in a porcine experimental endotoxemic model.Sci Rep. 2024 Nov 5;14(1):26807. doi: 10.1038/s41598-024-77483-7. Sci Rep. 2024. PMID: 39500994 Free PMC article.
-
The Effects of Pulmonary Artery Catheter on the Short-Term Outcomes of Patients Undergoing Off-Pump Coronary Artery Bypass Grafting: A Single-Center Retrospective Study.Rev Cardiovasc Med. 2024 May 22;25(5):183. doi: 10.31083/j.rcm2505183. eCollection 2024 May. Rev Cardiovasc Med. 2024. PMID: 39076489 Free PMC article.
-
A comparison of hemodynamic measurement methods during orthotopic liver transplantation: evaluating agreement and trending ability of PiCCO versus pulmonary artery catheter techniques.BMC Anesthesiol. 2024 Jun 6;24(1):201. doi: 10.1186/s12871-024-02582-x. BMC Anesthesiol. 2024. PMID: 38844869 Free PMC article.
-
Hemodynamic Monitoring Using a Pulmonary Artery Catheter Versus the Vigileo/FloTrac System during Elective Cardiac Surgery Based on Real-world Data in Japan.Ann Clin Epidemiol. 2022 Mar 11;4(3):81-91. doi: 10.37737/ace.22011. eCollection 2022. Ann Clin Epidemiol. 2022. PMID: 38504946 Free PMC article.
-
Carotid Blood Flow as a Surrogate for Pulse Contour Analysis in Assessment of Fluid Responsiveness: A Prospective, Observational, Single-Centre Study (Contour Study).Cureus. 2024 Jan 30;16(1):e53253. doi: 10.7759/cureus.53253. eCollection 2024 Jan. Cureus. 2024. PMID: 38435954 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous