Dual polarisation interferometry characterisation of DNA immobilisation and hybridisation detection on a silanised support

Biosens Bioelectron. 2006 Feb 15;21(8):1459-67. doi: 10.1016/j.bios.2005.06.009. Epub 2005 Aug 19.

Abstract

Dual polarisation interferometry is an analytical technique that allows the simultaneous determination of thickness, density and mass of a biological layer on a sensing waveguide surface in real time. We evaluated, for the first time, the ability of this technique to characterise the covalent immobilisation of single stranded probe DNA and the selective detection of target DNA hybridisation on a silanised support. Two immobilisation strategies have been evaluated: direct attachment of the probe molecule and a more complex chemistry employing a 1,2 homobifunctional crosslinker molecule. With this technique we demonstrate it was possible to determine probe orientation and measure probe coverage at different stages of the immobilisation process in real time and in a single experiment. In addition, by measuring simultaneously changes in thickness and density of the probe layer upon hybridisation of target DNA, it was possible to directly elucidate the impact that probe mobility had on hybridisation efficiency. Direct covalent attachment of an amine modified 19 mer resulted in a thickness change of 0.68 nm that was consistent with multipoint attachment of the probe molecule to the surface. Blocking with BSA formed a dense layer of protein molecules that absorbed between the probe molecules on the surface. The observed hybridisation efficiency to target DNA was approximately 35%. No further significant reorientation of the probe molecule occurred upon hybridisation. The initial thickness of the probe layer upon attachment to the crosslinker molecule was 0.5 nm. Significant reorientation of the probe molecule surface normal occurred upon hybridisation to target DNA. This indicated that the probe molecule had greater mobility to hybridise to target DNA. The observed hybridisation efficiency for target DNA was approximately 85%. The results show that a probe molecule attached to the surface via a crosslinker group is better able to hybridise to target DNA due to its greater mobility.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Biosensing Techniques / instrumentation*
  • Biosensing Techniques / methods
  • DNA / analysis*
  • DNA / chemistry*
  • Equipment Design
  • Equipment Failure Analysis
  • In Situ Hybridization / instrumentation*
  • In Situ Hybridization / methods
  • Interferometry / instrumentation*
  • Interferometry / methods
  • Microscopy, Polarization / instrumentation*
  • Microscopy, Polarization / methods
  • Oligonucleotide Array Sequence Analysis / instrumentation*
  • Oligonucleotide Array Sequence Analysis / methods
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Silicon / chemistry

Substances

  • DNA
  • Silicon