Repeat CT imaging and replanning during the course of IMRT for head-and-neck cancer

Int J Radiat Oncol Biol Phys. 2006 Feb 1;64(2):355-62. doi: 10.1016/j.ijrobp.2005.07.957. Epub 2005 Oct 26.

Abstract

Purpose: Many patients with head-and-neck (H&N) cancer have tumor shrinkage and/or weight loss during the course of radiotherapy. We conducted this retrospective study to determine the dosimetric effects of repeat computed tomography (CT) imaging and replanning during the course of intensity-modulated radiotherapy (IMRT) on both normal tissues and target volumes.

Methods and materials: A retrospective chart review identified 13 patients with H&N cancer treated with IMRT who had repeat CT imaging and replanning during the course of radiotherapy. The first IMRT plan for each patient was generated based on the original planning CT scan acquired before the start of treatment. Because of tumor shrinkage or weight loss during radiotherapy, a second CT scan was acquired, and a new plan was generated and used to complete the course of IMRT. CT-CT fusion was used to correct patient positioning differences between the scans. By using a commercial inverse IMRT planning system, a hybrid IMRT plan was generated for each patient by applying the beam configurations of the first IMRT plan (including the intensity profile of each beam) to the anatomy of the second CT scan. The dose-volume histograms of the actual and hybrid IMRT plans were compared using analysis of variance methods for repeated measures.

Results: All patients had locally advanced, nonmetastatic Stage III or IV disease, including 6 nasopharynx, 6 oropharynx, and 1 unknown primary site. All patients were treated with concurrent platinum-based chemotherapy. When replanning vs. not replanning was compared, the hybrid IMRT plans (without replanning) demonstrated reduced doses to target volumes and increased doses to critical structures. The doses to 95% (D95) of the planning target volumes of the gross tumor volume (PTVGTV) and the clinical target volume (PTVCTV) were reduced in 92% of patients, by 0.8-6.3 Gy (p=0.02) and 0.2-7.4 Gy (p=0.003), respectively. The maximum dose (Dmax) to the spinal cord increased in all patients (range, 0.2-15.4 Gy; p=0.003) and the brainstem Dmax increased in 85% of patients without replanning (range, 0.6-8.1 Gy; p=0.007).

Conclusions: Repeat CT imaging and replanning during the course of IMRT for selected patients with H&N cancer is essential to identify dosimetric changes and to ensure adequate doses to target volumes and safe doses to normal tissues. Future prospective studies with larger sample sizes will help to determine criteria for repeat CT imaging and IMRT replanning for H&N cancer patients undergoing radiotherapy.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Analysis of Variance
  • Brain Stem
  • Female
  • Head and Neck Neoplasms / diagnostic imaging*
  • Head and Neck Neoplasms / radiotherapy*
  • Humans
  • Male
  • Middle Aged
  • Nasopharyngeal Neoplasms / diagnostic imaging
  • Nasopharyngeal Neoplasms / radiotherapy
  • Oropharyngeal Neoplasms / diagnostic imaging
  • Oropharyngeal Neoplasms / radiotherapy
  • Radiotherapy Dosage
  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy, Intensity-Modulated / methods*
  • Retrospective Studies
  • Spinal Cord
  • Statistics, Nonparametric
  • Tomography, X-Ray Computed / methods*
  • Weight Loss