Evaluation of ceramic and membrane diffusers under operating conditions with the dynamic offgas method

Water Environ Res. 2005 Sep-Oct;77(5):447-54. doi: 10.2175/106143005x67359.

Abstract

The aeration systems of two full-scale, activated-sludge basins were compared during a period of three years, under the same operating conditions, using dynamic offgas testing. Only the material of the diffuser was different (membrane versus ceramic-tube diffusers). The investigation has shown that, although the membrane diffusers have higher initial standard-oxygen-transfer efficiency (alphaSOTE) and standard-aeration efficiency (alphaSAE), these decreased over time, while the alphaSAE of the ceramic diffusers started lower, but increased slightly over the whole period. A cost comparison makes clear how important it is to evaluate the aeration system under process conditions. The operating costs were the dominant factor (approximately 10x higher than capital costs), and operating costs were approximately 20% higher for membrane versus ceramic diffusers. The poor performance of the membrane-tube diffusers under process conditions could be explained on the basis of the actual alphaAE values in the basin, not the standardized values.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Bioreactors
  • Ceramics*
  • Diffusion
  • Medical Waste Disposal / economics
  • Medical Waste Disposal / instrumentation*
  • Medical Waste Disposal / methods*
  • Oxygen / chemistry
  • Sewage / chemistry
  • Time Factors
  • Waste Disposal, Fluid / economics
  • Waste Disposal, Fluid / instrumentation*
  • Waste Disposal, Fluid / methods*

Substances

  • Medical Waste Disposal
  • Sewage
  • Oxygen