A technique to reposition sinotubular junction in aortic valve reimplantation procedures with the De Paulis Valsalva graft

Eur J Cardiothorac Surg. 2006 Jan;29(1):107-9. doi: 10.1016/j.ejcts.2005.10.028. Epub 2005 Dec 6.

Abstract

Sinotubular junction reconstruction in reimplantation type of valve-sparing aortic procedure can present some problem when a Valsalva graft is used. Since in the Valsalva graft the sinotubular junction height is predetermined, correct matching with native commissures height can be difficult. We propose a method by which it is possible to create a new sinotubular junction in Valsalva graft without altering its original configuration.

Publication types

  • Case Reports

MeSH terms

  • Aortic Aneurysm / surgery
  • Aortic Valve / abnormalities
  • Aortic Valve / surgery
  • Aortic Valve Insufficiency / surgery*
  • Heart Valve Prosthesis
  • Heart Valve Prosthesis Implantation / methods
  • Humans
  • Male
  • Middle Aged
  • Replantation / methods
  • Sinus of Valsalva / surgery*