Variation of the time to aortic enhancement of fixed-duration versus fixed-rate injection protocols

AJR Am J Roentgenol. 2006 Jan;186(1):185-92. doi: 10.2214/AJR.04.0923.

Abstract

Objective: The objective of the study was to clarify whether a fixed-duration injection protocol is useful in determining the optimal scan delay time without the need for a bolus-tracking technique.

Materials and methods: Three hundred eighteen patients underwent a helical CT examination using a bolus-tracking technique. All the examinations were performed after administering a nonionic contrast medium (300 or 370 mg I/mL; 2 mL/kg of body weight for patients weighing < or = 75 kg, 150 mL for those weighing > 75 kg). The patients were assigned to one of three groups according to the injection protocol. The injection rate was alternated to 3 or 4 mL/sec in group 1. The injection duration was 38 or 47 sec in groups 2 and 3, respectively. The aortic arrival time and the 100-H threshold time in each patient were measured. The mean values and the variations in the aortic arrival time and 100-H threshold time according to the injection protocols and the contrast media were compared.

Results: The mean variations (+/- SD) of aortic arrival times and 100-H thresholds in group 2 (aortic arrival time = 16.1 +/- 2.7 sec, 100-H threshold time = 19.6 +/- 2.9 sec) were smaller than in groups 1 (16.3 +/- 3.0 sec and 19.9 +/- 3.7 sec, respectively) and 3 (16.8 +/- 3.5 sec and 20.4 +/- 4.1 sec, respectively). However, the range of aortic arrival times and 100-H threshold times was more than 10 sec for all groups. The mean aortic arrival time and 100-H threshold time for all patients were 16.5 and 20.0 sec, respectively, and did not vary significantly with the injection protocol and concentration of contrast medium.

Conclusion: The individual variations of the aortic arrival and 100-H threshold times can be reduced using a fixed-duration injection technique, but there are still substantial variations. Therefore, a bolus-tracking technique is recommended for optimal timing of arterial phase scanning.

Publication types

  • Randomized Controlled Trial

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Contrast Media / administration & dosage*
  • Female
  • Humans
  • Injections, Intravenous / methods*
  • Iohexol / administration & dosage*
  • Iopamidol / administration & dosage*
  • Male
  • Middle Aged
  • Radiography, Abdominal*
  • Time Factors
  • Tomography, Spiral Computed*

Substances

  • Contrast Media
  • Iohexol
  • Iopamidol