Analytically exact correction scheme for signal extraction from noisy magnitude MR signals
- PMID: 16488635
- DOI: 10.1016/j.jmr.2006.01.016
Analytically exact correction scheme for signal extraction from noisy magnitude MR signals
Abstract
An analytically exact method is proposed to extract the signal intensity and the noise variance simultaneously from noisy magnitude MR signals. This method relies on a fixed point formula of signal-to-noise ratio (SNR) and a correction factor. The correction factor, which is a function of SNR, establishes a fundamental link between the variance of the magnitude MR signal and the variance of the underlying Gaussian noise in the two quadrature channels. A more general but very similar method is developed for parallel signal acquisitions with multiple receiver coils. In the context of MR imaging, the proposed method can be carried out on a pixel-by-pixel basis if the mean and the standard deviation of the magnitude signal are available.
Similar articles
-
Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters.J Magn Reson Imaging. 2007 Aug;26(2):375-85. doi: 10.1002/jmri.20969. J Magn Reson Imaging. 2007. PMID: 17622966
-
Effective noise estimation and filtering from correlated multiple-coil MR data.Magn Reson Imaging. 2013 Feb;31(2):272-85. doi: 10.1016/j.mri.2012.07.006. Epub 2012 Oct 31. Magn Reson Imaging. 2013. PMID: 23122024
-
Noise correlations and SNR in phased-array MRS.NMR Biomed. 2010 Jan;23(1):66-73. doi: 10.1002/nbm.1429. NMR Biomed. 2010. PMID: 19708042
-
MR spectroscopy quantitation: a review of time-domain methods.NMR Biomed. 2001 Jun;14(4):233-46. doi: 10.1002/nbm.695. NMR Biomed. 2001. PMID: 11410941 Review.
-
Common processing of in vivo MR spectra.NMR Biomed. 2001 Jun;14(4):224-32. doi: 10.1002/nbm.707. NMR Biomed. 2001. PMID: 11410940 Review.
Cited by
-
Signal-to-noise ratio increase in carotid atheroma MRI: a comparison of 1.5 and 3 T.Br J Radiol. 2012 Jul;85(1015):937-44. doi: 10.1259/bjr/70496948. Epub 2012 Jan 31. Br J Radiol. 2012. PMID: 22294703 Free PMC article.
-
Mapping the human connectome using diffusion MRI at 300 mT/m gradient strength: Methodological advances and scientific impact.Neuroimage. 2022 Jul 1;254:118958. doi: 10.1016/j.neuroimage.2022.118958. Epub 2022 Feb 23. Neuroimage. 2022. PMID: 35217204 Free PMC article. Review.
-
Diffusion MRI signal cumulants and hepatocyte microstructure at fixed diffusion time: Insights from simulations, 9.4T imaging, and histology.Magn Reson Med. 2022 Jul;88(1):365-379. doi: 10.1002/mrm.29174. Epub 2022 Feb 18. Magn Reson Med. 2022. PMID: 35181943 Free PMC article.
-
Analytically exact spiral scheme for generating uniformly distributed points on the unit sphere.J Comput Sci. 2011 Mar 1;2(1):88-91. doi: 10.1016/j.jocs.2010.12.003. J Comput Sci. 2011. PMID: 21516173 Free PMC article.
-
Optimization of a free water elimination two-compartment model for diffusion tensor imaging.Neuroimage. 2014 Dec;103:323-333. doi: 10.1016/j.neuroimage.2014.09.053. Epub 2014 Sep 28. Neuroimage. 2014. PMID: 25271843 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical