Medium-term results of thrust plate prostheses for osteoarthritis of the hip

Bull Hosp Jt Dis. 2005;63(1-2):28-30.

Abstract

We retrospectively evaluated the results of 61 patients (67 hips) who underwent total hip arthroplasty using the thrust plate prosthesis (TPP) for osteoarthritis of the hip joint. All patients were followed-up at least two years (mean: 37.2 months). Mean preoperative Harris hip score improved from 45.8 (SD: 13.5) to 94.9 (SD: 5.4) points postoperatively. Revision was performed in five cases. Medium-term results of TPP are promising.

MeSH terms

  • Adult
  • Aged
  • Arthroplasty, Replacement, Hip*
  • Female
  • Hip Joint / diagnostic imaging
  • Hip Prosthesis*
  • Humans
  • Male
  • Middle Aged
  • Osteoarthritis, Hip / diagnostic imaging
  • Osteoarthritis, Hip / surgery*
  • Radiography
  • Retrospective Studies
  • Treatment Outcome