Transmuscular migration of 240 silicone encircling band
Eye (Lond)
.
2006 Dec;20(12):1456-8.
doi: 10.1038/sj.eye.6702334.
Epub 2006 Mar 17.
Authors
A J Kreis
,
G Klainguti
,
E H Bovey
,
T J Wolfensberger
PMID:
16543922
DOI:
10.1038/sj.eye.6702334
No abstract available
Publication types
Case Reports
Letter
Review
MeSH terms
Adult
Foreign-Body Migration*
Humans
Male
Myopia / surgery*
Oculomotor Muscles
Prostheses and Implants*
Prosthesis Failure
Retinal Detachment / surgery*
Silicones
Substances
Silicones