Pattern electroretinogram in glaucoma
- PMID: 16552256
- PMCID: PMC2756426
- DOI: 10.1097/01.icu.0000193082.44938.3c
Pattern electroretinogram in glaucoma
Abstract
Purpose of review: Several studies have shown that the pattern electroretinogram, a direct, objective method of measuring retinal ganglion cell function, is altered early in ocular hypertension and glaucoma. Renewed interest in the pattern electroretinogram for early detection of pre-perimetric glaucoma has been sparked by noninvasive and reproducible methods of recording using skin electrodes.
Recent findings: With the noninvasive pattern electroretinogram, response abnormalities have been detected in up to 50% of glaucoma suspects with normal standard perimetry. In early glaucoma (with either normal or high intraocular pressure), a reduction of intraocular pressure has sometimes yielded improvement in pattern electroretinogram amplitude. A prolonged steady-state stimulus presentation reduces the pattern electroretinogram amplitude and increases optic nerve blood flow in normal subjects, suggesting that sustained activity of retinal ganglion cells is physiologically associated with autoregulatory changes of the neural-vascular system. It is unknown whether this autoregulation is altered in glaucoma. The multifocal pattern electroretinogram does not seem to have an advantage over the pattern electroretinogram in the early detection of glaucoma. The photopic negative response of the diffuse flash electroretinogram has shown changes in glaucoma, but may not be able to detect retinal dysfunction in normal tension glaucoma.
Summary: The pattern electroretinogram is a noninvasive, direct, objective method that may be useful to clinicians in detecting early retinal ganglion cell dysfunction in glaucoma suspects. The pattern electroretinogram may also optimize treatment strategies based on improvement of retinal ganglion cell function.
Figures
Similar articles
-
Restoration of retinal ganglion cell function in early glaucoma after intraocular pressure reduction: a pilot study.Ophthalmology. 2005 Jan;112(1):20-7. doi: 10.1016/j.ophtha.2004.09.002. Ophthalmology. 2005. PMID: 15629815 Free PMC article.
-
Photopic negative response versus pattern electroretinogram in early glaucoma.Invest Ophthalmol Vis Sci. 2013 Feb 1;54(2):1182-91. doi: 10.1167/iovs.12-11201. Invest Ophthalmol Vis Sci. 2013. PMID: 23307968 Clinical Trial.
-
[The pattern electroretinogram in early glaucoma and ocular hypertension].Fortschr Ophthalmol. 1990;87(6):591-3. Fortschr Ophthalmol. 1990. PMID: 2086401 German.
-
Electrophysiological tests in evaluation of glaucoma and ocular hypertension treatment--up to date knowledge. A review.Klin Oczna. 2013;115(2):148-51. Klin Oczna. 2013. PMID: 24059033 Review.
-
Electroretinography in glaucoma diagnosis.Curr Opin Ophthalmol. 2016 Mar;27(2):118-24. doi: 10.1097/ICU.0000000000000241. Curr Opin Ophthalmol. 2016. PMID: 26720775 Free PMC article. Review.
Cited by
-
Correlations between Steady-State Pattern Electroretinogram and Humphrey Visual Field Analyzer Global Indices and Their Associations with Retinal Ganglion Cell Layer-Inner Plexiform Layer Thickness in Glaucoma Suspects.J Ophthalmol. 2024 Mar 11;2024:2443887. doi: 10.1155/2024/2443887. eCollection 2024. J Ophthalmol. 2024. PMID: 38500553 Free PMC article.
-
Effect of eccentric fixation on the steady-state pattern electroretinogram.Doc Ophthalmol. 2024 Apr;148(2):87-95. doi: 10.1007/s10633-024-09967-w. Epub 2024 Feb 28. Doc Ophthalmol. 2024. PMID: 38416305 Free PMC article.
-
Utility of Light-Adapted Full-Field Electroretinogram ON and OFF Responses for Detecting Glaucomatous Functional Damage.Transl Vis Sci Technol. 2023 Aug 1;12(8):16. doi: 10.1167/tvst.12.8.16. Transl Vis Sci Technol. 2023. PMID: 37594448 Free PMC article.
-
Pattern Electroretinogram in Ocular Hypertension, Glaucoma Suspect and Early Manifest Glaucoma Eyes: A Systematic Review and Meta-analysis.Ophthalmol Sci. 2023 Apr 29;3(4):100322. doi: 10.1016/j.xops.2023.100322. eCollection 2023 Dec. Ophthalmol Sci. 2023. PMID: 37334035 Free PMC article.
-
Assessment of the uniform field electroretinogram for mouse retinal ganglion cell functional analysis.Doc Ophthalmol. 2023 Aug;147(1):29-43. doi: 10.1007/s10633-023-09933-y. Epub 2023 Apr 28. Doc Ophthalmol. 2023. PMID: 37106219
References
-
- Riggs LA, Johnson EP, Schick AML. Electrical responses of the human eye to moving stimulus pattern. Science. 1964;144:567–568. - PubMed
-
- Bach M, Hawlina M, Holder GE, et al. for the International Society for Clinical Electrophysiology of Vision. Standard for pattern electroretinography. Doc Ophthalmol. 2000;101:11–18. - PubMed
-
- Maffei L, Fiorentini A. Electroretinographic responses to alternating gratings before and after section of the optic nerve. Science. 1981;211:953–955. - PubMed
-
- Fiorentini A, Maffei L, Pirchio M, et al. The ERG in response to alternating gratings in patients with diseases of the peripheral visual pathway. Invest Ophthalmol Vis Sci. 1981;21:490–493. - PubMed
-
- Zrenner E. The physiological basis of the pattern electroretinogram. In: Osborne N, Chader G, editors. Progress in Retinal Research. Vol. 9 Oxford: Pergamon Press; 1990.