18F-FDG PET/CT for detecting nodal metastases in patients with oral cancer staged N0 by clinical examination and CT/MRI

J Nucl Med. 2006 May;47(5):755-62.

Abstract

(18)F-FDG PET has a high accuracy in staging head and neck cancer, but its role in patients with clinically and radiographically negative necks (N0) is less clear. In particular, the value of combined PET/CT has not been determined in this group of patients.

Methods: In a prospective study, 31 patients with oral cancer and no evidence of lymph node metastases by clinical examination or CT/MRI underwent (18)F-FDG PET/CT before elective neck dissection. PET/CT findings were recorded by neck side (left or right) and lymph node level. PET/CT findings were compared with histopathology of dissected nodes, which was the standard of reference.

Results: Elective neck dissections (26 unilateral, 5 bilateral; a total of 36 neck sides), involving 142 nodal levels, were performed. Only 13 of 765 dissected lymph nodes harbored metastases. Histopathology revealed nodal metastases in 9 of 36 neck sides and 9 of 142 nodal levels. PET was TP in 6 nodal levels (6 neck sides), false-negative in 3 levels (3 neck sides), true-negative in 127 levels (23 neck sides), and false-positive in 6 levels (4 neck sides). The 3 false-negative findings occurred in metastases smaller than 3 mm or because of inability to distinguish between primary tumor and adjacent metastasis. TP and false-positive nodes exhibited similar standardized uptakes (4.8 +/- 1.1 vs. 4.2 +/- 1.0; P = not significant). Sensitivity and specificity were 67% and 85% on the basis of neck sides and 67% and 95% on the basis of number of nodal levels, respectively. If a decision regarding the need for neck dissection had been based solely on PET/CT, 3 false-negative necks would have been undertreated, and 4 false-positive necks would have been overtreated.

Conclusion: (18)F-FDG PET/CT can identify lymph node metastases in a segment of patients with oral cancer and N0 neck. A negative test can exclude metastatic deposits with high specificity. Despite reasonably high overall accuracy, however, the clinical application of PET/CT in the N0 neck may be limited by the combination of limited sensitivity for small metastatic deposits and a relatively high number of false-positive findings. The surgical management of the N0 neck should therefore not be based on PET/CT findings alone.

Publication types

  • Clinical Trial

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • False Positive Reactions
  • Female
  • Fluorodeoxyglucose F18 / chemistry*
  • Humans
  • Lymphatic Metastasis
  • Magnetic Resonance Imaging / methods
  • Male
  • Middle Aged
  • Mouth Neoplasms / diagnosis*
  • Mouth Neoplasms / radiotherapy*
  • Neoplasm Metastasis
  • Positron-Emission Tomography / methods*
  • Tomography, X-Ray Computed / methods*

Substances

  • Fluorodeoxyglucose F18