Short thyromental distance: a predictor of difficult intubation or an indicator for small blade selection?
- PMID: 16732082
- DOI: 10.1097/00000542-200606000-00006
Short thyromental distance: a predictor of difficult intubation or an indicator for small blade selection?
Abstract
Background: Short thyromental distance (TMD; < 5 cm) has been correlated with difficult direct laryngoscopic intubation in adult patients. The authors hypothesized that a smaller Macintosh curved blade (No. 2 MCB) would improve the predicted difficult laryngoscopy in short-TMD patients over that with a standard Macintosh curved blade (No. 3 MCB).
Methods: In a preliminary study of 11 consenting adults (7 females and 4 males), American Society of Anesthesiologists physical status I and TMD < or = 5 cm, lateral neck radiographs were recorded during laryngoscopy with a No. 2 and No. 3 MCB in sequential fashion. In a prospective clinical study, laryngoscopy and tracheal intubation were evaluated in 83 adult patients with TMD < or = 5 cm by randomly assigning them to two groups for the blade used at first intubation. Those who failed intubation with the first blade were switched to the alternate blade. In total 100 laryngoscopies and intubations were performed: the No. 2 MCB (n = 50) and the No. 3 MCB (n = 50).
Results: Lateral neck radiographs recorded at the best laryngeal view revealed that the tip of the No. 2 MCB was proximal to the hyoid body with the No. 2 MCB and distal to it with the No. 3 MCB. The intubation distance (C5 to blade tip) on neck radiographs with the No. 2 MCB was significantly greater than it was with the No. 3 MCB for similar anterior jaw displacement. In the clinical study, the laryngoscopic grade with the No. 2 blade was considered easy (median, 2B), better than the grade with the No. 3 MCB (median, 3). When the No. 2 MCB was used, external laryngeal pressure improved the laryngoscopic grade (1, full glottic view) in 46% of patients. In contrast, when the No. 3 MCB was used, pressure improved the grade in only 10% of the patients. Intubation time with the No. 2 MCB was significantly (P < 0.05) less than it was in patients with No. 3 MCB. Overall, 14 patients who failed intubation with the No. 3 MCB were switched to the No. 2 MCB, and intubation was successful with an easy laryngoscopic grade. Three patients who failed intubation with the No. 2 MCB were switched to the No. 3 MCB.
Conclusions: The predicted difficult laryngoscopy and intubation with the use of the adult No. 3 MCB in standard adult patients with a TMD < or = 5 cm is significantly easier with use of the smaller No. 2 MCB.
Comment in
-
Use of Macintosh laryngoscope No. 2 for adult patients with a short thyromental distance.Anesthesiology. 2007 Feb;106(2):403; author reply 403-4. doi: 10.1097/00000542-200702000-00038. Anesthesiology. 2007. PMID: 17264745 No abstract available.
Similar articles
-
Effect of the Macintosh curved blade size on direct laryngoscopic view in edentulous patients.Am J Emerg Med. 2018 Jan;36(1):120-123. doi: 10.1016/j.ajem.2017.09.050. Epub 2017 Sep 28. Am J Emerg Med. 2018. PMID: 28974373
-
A Macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways.Anesth Analg. 2009 Sep;109(3):825-31. doi: 10.1213/ane.0b013e3181ae39db. Anesth Analg. 2009. PMID: 19690253 Clinical Trial.
-
Management of the predicted difficult airway: a comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the GlideScope.Eur J Anaesthesiol. 2010 Jan;27(1):24-30. doi: 10.1097/EJA.0b013e32832d328d. Eur J Anaesthesiol. 2010. PMID: 19809328 Clinical Trial.
-
The use of paraglossal straight blade laryngoscopy in difficult tracheal intubation.Anaesthesia. 1997 Jun;52(6):552-60. doi: 10.1111/j.1365-2222.1997.129-az0125.x. Anaesthesia. 1997. PMID: 9203882 Review.
-
Predictive performance of thyromental height for difficult laryngoscopies in adults: a systematic review and meta-analysis.Braz J Anesthesiol. 2023 Jul-Aug;73(4):491-499. doi: 10.1016/j.bjane.2021.06.015. Epub 2021 Jul 9. Braz J Anesthesiol. 2023. PMID: 34252454 Free PMC article. Review.
Cited by
-
Evaluation and comparison of sonographic difficult airway assessment parameters with clinical airway predictors.J Anaesthesiol Clin Pharmacol. 2024 Jul-Sep;40(3):422-431. doi: 10.4103/joacp.joacp_181_23. Epub 2023 Oct 18. J Anaesthesiol Clin Pharmacol. 2024. PMID: 39391664 Free PMC article.
-
Machine Learning Predictions and Identifying Key Predictors for Safer Intubation: A Study on Video Laryngoscopy Views.J Pers Med. 2024 Aug 25;14(9):902. doi: 10.3390/jpm14090902. J Pers Med. 2024. PMID: 39338156 Free PMC article.
-
Assessment of Different Indices as Predictors of Difficult Airway in Obese Patients.Cureus. 2024 Feb 26;16(2):e55005. doi: 10.7759/cureus.55005. eCollection 2024 Feb. Cureus. 2024. PMID: 38414514 Free PMC article.
-
Influence of Curved Video Laryngoscope Blade Sizes and Patient Heights on Video Laryngoscopic Views: A Randomized Controlled Trial.J Pers Med. 2024 Feb 15;14(2):209. doi: 10.3390/jpm14020209. J Pers Med. 2024. PMID: 38392642 Free PMC article.
-
Comparison of Ultrasound Parameters and Clinical Parameters in Airway Assessment for Prediction of Difficult Laryngoscopy and Intubation: An Observational Study.Cureus. 2023 Jul 5;15(7):e41392. doi: 10.7759/cureus.41392. eCollection 2023 Jul. Cureus. 2023. PMID: 37546081 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous