Clinical comparison of a novel breast DXA technique to mammographic density
- PMID: 16752583
- DOI: 10.1118/1.2193691
Clinical comparison of a novel breast DXA technique to mammographic density
Abstract
We compare mammography breast density (BD(MD)) to the measure of breast composition using a clinical dual energy absorptiometry (DXA) system (BD(DXA)) calibrated to measure breast density. A DXA scanning protocol was developed to scan breasts isolated in the DXA scan field in either a prone pendulous or decubitus mediolateral position. A total of 17 participants were recruited among women undergoing clinical mammography examinations. Each participant had duplicate DXA scans and duplicate craniocaudal-view mammograms of their right breast with repositioning between each scan and one DXA and one craniocaudal-view mammogram of their left breast. The in vivo repeatability (RMS SD) of BD(DXA) and BD(MD) on duplicate scans was found to be 1.2% for BD(DXA) and 1.4% for BD(MD) when repeat BD(MD) measures were made on the same day. When repeat BD(MD) measures of the same breast were made more than 50 days apart, the repeatability decreased to 5.5%. Left and right breast measurements were highly correlated with both techniques at r2 = 0.98 for BD(DXA) and r2 = 0.86 for BD(MD). Moderate correlation (r2 = 0.52) was found between BD(DXA) and BD(MD) measurements. However, after recalibrating the DXA system to mammography reference materials, negative percent fibroglandular values were measured for the most fatty breasts. Thus, our results are reproducible and accurate to common mammography tissue standards, but did not accurately reflect true percent fibroglandular levels and further development of phantom standards are necessary. We conclude that breast composition can be precisely evaluated and assessed with clinical DXA densitometers at a lower dose than with mammographic breast density methods.
Similar articles
-
Novel use of single X-ray absorptiometry for measuring breast density.Technol Cancer Res Treat. 2005 Apr;4(2):173-82. doi: 10.1177/153303460500400206. Technol Cancer Res Treat. 2005. PMID: 15773786
-
Mammographic density and cancer detection: does digital imaging challenge our current understanding?Acad Radiol. 2014 Nov;21(11):1377-85. doi: 10.1016/j.acra.2014.06.004. Epub 2014 Aug 2. Acad Radiol. 2014. PMID: 25097013
-
Comparison of breast density measured by dual energy X-ray absorptiometry with mammographic density among adult women in Hawaii.Cancer Epidemiol. 2011 Apr;35(2):188-93. doi: 10.1016/j.canep.2010.06.009. Epub 2010 Aug 4. Cancer Epidemiol. 2011. PMID: 20688593 Free PMC article.
-
Can mammographic assessments lead to consider density as a risk factor for breast cancer?Eur J Radiol. 2013 Mar;82(3):404-11. doi: 10.1016/j.ejrad.2010.01.001. Epub 2010 Feb 4. Eur J Radiol. 2013. PMID: 20133095 Review.
-
What effect does mammographic breast density have on lesion detection in digital mammography?Clin Radiol. 2014 Apr;69(4):333-41. doi: 10.1016/j.crad.2013.11.014. Epub 2014 Jan 11. Clin Radiol. 2014. PMID: 24424328 Review.
Cited by
-
The distribution of breast density in women aged 18 years and older.Breast Cancer Res Treat. 2024 Mar 18. doi: 10.1007/s10549-024-07269-y. Online ahead of print. Breast Cancer Res Treat. 2024. PMID: 38498102
-
Breast composition during and after puberty: the Chilean Growth and Obesity Cohort Study.Breast Cancer Res. 2024 Mar 12;26(1):45. doi: 10.1186/s13058-024-01793-x. Breast Cancer Res. 2024. PMID: 38475816 Free PMC article.
-
Alternative methods to measure breast density in younger women.Br J Cancer. 2023 May;128(9):1701-1709. doi: 10.1038/s41416-023-02201-5. Epub 2023 Feb 24. Br J Cancer. 2023. PMID: 36828870 Free PMC article.
-
Variability in urinary phthalates, phenols, and parabens across childhood and relation to adolescent breast composition in Chilean girls.Environ Int. 2022 Dec;170:107586. doi: 10.1016/j.envint.2022.107586. Epub 2022 Oct 19. Environ Int. 2022. PMID: 36302292 Free PMC article.
-
The Chilean Maternal-Infant Cohort Study-II in the COVID-19 Era: A Study Protocol.Front Public Health. 2022 Jul 14;10:904668. doi: 10.3389/fpubh.2022.904668. eCollection 2022. Front Public Health. 2022. PMID: 35910889 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical