Method comparison in the clinical laboratory
- PMID: 16967409
- DOI: 10.1111/j.1939-165x.2006.tb00131.x
Method comparison in the clinical laboratory
Abstract
Studies comparing a new method with an established method, to assess whether the new measurements are comparable with existing ones, are frequently conducted in clinical pathology laboratories. Assessment usually involves statistical analysis of paired results from the 2 methods to objectively investigate sources of analytical error (total, random, and systematic). In this review article, the types of errors that can be assessed in performing this task are described, and a general protocol for comparison of quantitative methods is recommended. The typical protocol has 9 steps: 1) state the purpose of the experiment, 2) establish a theoretical basis for the method comparison experiment, 3) become familiar with the new method, 4) obtain estimates of random error for both methods, 5) estimate the number of samples to be included in the method comparison experiment, 6) define acceptable difference between the 2 methods, 7) measure the patient samples, 8) analyze the data, and 9) judge acceptability. The protocol includes the essential investigations and decisions needed to objectively assess the overall analytical performance of a new method compared to a reference or established method. The choice of statistical methods and recommendations of decision criteria within the stages are discussed. Use of the protocol for decision-making is exemplified by the comparison of 2 methods for measuring alanine aminotransferase activity in serum from dogs. Finally, a protocol for comparing simpler semiquantitative methods with established methods that measure on a continuous scale is suggested.
Similar articles
-
ASVCP guidelines: allowable total error guidelines for biochemistry.Vet Clin Pathol. 2013 Dec;42(4):424-36. doi: 10.1111/vcp.12101. Vet Clin Pathol. 2013. PMID: 24320779
-
Reference intervals: an essential, expanding, and occasionally equivocal standard.Vet Clin Pathol. 2010 Jun;39(2):131-2. doi: 10.1111/j.1939-165X.2010.00235.x. Vet Clin Pathol. 2010. PMID: 20624261 No abstract available.
-
Internal quality control of a turbidimetric immunoassay for canine serum C-reactive protein based on pooled patient samples.Vet Clin Pathol. 2004;33(3):139-44. doi: 10.1111/j.1939-165x.2004.tb00363.x. Vet Clin Pathol. 2004. PMID: 15334348
-
The preanalytic phase in veterinary clinical pathology.Vet Clin Pathol. 2015 Mar;44(1):8-25. doi: 10.1111/vcp.12206. Epub 2014 Dec 1. Vet Clin Pathol. 2015. PMID: 25438659 Review.
-
Recognizing and Reducing Analytical Errors and Sources of Variation in Clinical Pathology Data in Safety Assessment Studies.Toxicol Pathol. 2017 Feb;45(2):281-287. doi: 10.1177/0192623316672945. Epub 2016 Nov 15. Toxicol Pathol. 2017. PMID: 28178899 Review.
Cited by
-
Serum protein electrophoresis in European mink (Mustela lutreola): reference intervals and comparison of agarose gel electrophoresis and capillary zone electrophoresis.Vet Q. 2024 Dec;44(1):1-11. doi: 10.1080/01652176.2024.2318195. Epub 2024 Feb 22. Vet Q. 2024. PMID: 38389258 Free PMC article.
-
Validity of BiliDx as a point-of-care bilirubin measurement device to diagnose and monitor neonatal jaundice at Muhimbili National Hospital, an observational study.BMC Pediatr. 2024 Feb 13;24(1):114. doi: 10.1186/s12887-024-04565-w. BMC Pediatr. 2024. PMID: 38350890 Free PMC article.
-
Comparison of Liver Function Test Results between Architect C8000 and COBAS C501 Automatic Chemistry Analyzer.Arch Razi Inst. 2023 Jun 30;78(3):1141-1146. doi: 10.22092/ARI.2022.360419.2584. eCollection 2023 Jun. Arch Razi Inst. 2023. PMID: 38028833 Free PMC article.
-
Evaluation of a Manual Cytocentrifuge versus the Standard Automated Cytocentrifuge in the Analysis of Canine Cerebrospinal Fluid: A Case Series of 55 Dogs.Vet Sci. 2023 Oct 24;10(11):631. doi: 10.3390/vetsci10110631. Vet Sci. 2023. PMID: 37999454 Free PMC article.
-
Evaluation of canine and feline leukocyte differential counts obtained with the scil vCell 5 compared to the Advia 2120 hematology analyzer and a manual method.J Vet Diagn Invest. 2023 Nov;35(6):679-697. doi: 10.1177/10406387231187899. Epub 2023 Aug 23. J Vet Diagn Invest. 2023. PMID: 37612877 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical