Accuracy of dual-source CT coronary angiography: First experience in a high pre-test probability population without heart rate control

Eur Radiol. 2006 Dec;16(12):2739-47. doi: 10.1007/s00330-006-0474-0. Epub 2006 Sep 19.

Abstract

The aim of this study was to assess the diagnostic accuracy of dual-source computed tomography (DSCT) for evaluation of coronary artery disease (CAD) in a population with extensive coronary calcifications without heart rate control. Thirty patients (24 male, 6 female, mean age 63.1+/-11.3 years) with a high pre-test probability of CAD underwent DSCT coronary angiography and invasive coronary angiography (ICA) within 14+/-9 days. No beta-blockers were administered prior to the scan. Two readers independently assessed image quality of all coronary segments with a diameter > or =1.5 mm using a four-point score (1: excellent to 4: not assessable) and qualitatively assessed significant stenoses as narrowing of the luminal diameter >50%. Causes of false-positive (FP) and false-negative (FN) ratings were assigned to calcifications or motion artifacts. ICA was considered the standard of reference. Mean body mass index was 28.3+/-3.9 kg/m2 (range 22.4-36.3 kg/m2), mean heart rate during CT was 70.3+/-14.2 bpm (range 47-102 bpm), and mean Agatston score was 821+/-904 (range 0-3,110). Image quality was diagnostic (scores 1-3) in 98.6% (414/420) of segments (mean image quality score 1.68+/-0.75); six segments in three patients were considered not assessable (1.4%). DSCT correctly identified 54 of 56 significant coronary stenoses. Severe calcifications accounted for false ratings in nine segments (eight FP/one FN) and motion artifacts in two segments (one FP/one FN). Overall sensitivity, specificity, positive and negative predictive value for evaluating CAD were 96.4, 97.5, 85.7, and 99.4%, respectively. First experience indicates that DSCT coronary angiography provides high diagnostic accuracy for assessment of CAD in a high pre-test probability population with extensive coronary calcifications and without heart rate control.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Artifacts
  • Calcinosis / diagnostic imaging
  • Chi-Square Distribution
  • Coronary Angiography / methods*
  • Coronary Disease / diagnostic imaging*
  • Female
  • Heart Rate / physiology
  • Humans
  • Male
  • Middle Aged
  • Predictive Value of Tests
  • Risk Factors
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed*