Stereospecific determination of cis- and trans-resveratrol in rat plasma by HPLC: application to pharmacokinetic studies

Biomed Chromatogr. 2007 Mar;21(3):257-65. doi: 10.1002/bmc.747.

Abstract

A simple, accurate, precise, specific and reproducible high-performance liquid chromatography (HPLC) method was developed for simultaneous determination of resveratrol isomers in rat plasma. Cis-resveratrol was made by exposure of a trans-resveratrol solution to sunlight for 5 days followed by separation by HPLC and identification by mass spectrometry (MS). The assay procedure involved simple liquid-liquid extraction of resveratrol isomers and internal standard (IS, caffeine) from a small plasma volume directly into acetonitrile. The supernatant liquid was added an equal volume of water and injected onto a Hypersil ODS(2) C(18) column (5 microm, 4.6 x 250 mm). Mobile phase consisting of methanol and distilled water was used at a flow rate of 1.0 mL/min for the effective separation of cis-, trans-resveratrol and caffeine (IS). The detection of the analyte peak was achieved by monitoring the eluate using a UV detector set at 303 nm. The ratio of peak area of analyte to IS was used for quantification of plasma samples. Nominal retention times of cis-, trans-resveratrol and IS were 3.2, 4.3 and 6.1 min, respectively. The calibration curve was linear ranging from 0.066 to 6.64 and 0.134 to 13.4 microg/mL with correlation coefficients of 0.9998 and 0.9997 for trans and cis isomers, respectively. The absolute recovery of both isomers was more than 85%. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.066, 0.664 and 6.64 microg/mL of trans-resveratrol, were in the range 2.37-6.95% relative standard deviation (RSD) and 0.77-6.97% RSD, respectively. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.134, 1.34 and 13.4 microg/mL of cis-resveratrol, were in the range 1.93-3.72% relative standard deviation (RSD) and 1.13-6.57% RSD, respectively. Both analytes and IS were stable in the battery of stability studies and freeze-thaw cycles. Resveratrol isomers were found to be stable for a period of 30 days on storage at -20 degrees C. The application of the assay to determine the pharmacokinetic disposition after a single oral dose to rats is described.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Caffeine / standards
  • Calibration / standards
  • Chromatography, High Pressure Liquid / methods*
  • Drug Stability
  • Molecular Structure
  • Plasma / chemistry
  • Rats
  • Rats, Sprague-Dawley
  • Reproducibility of Results
  • Resveratrol
  • Sensitivity and Specificity
  • Spectrometry, Mass, Electrospray Ionization / methods*
  • Spectrophotometry, Ultraviolet / methods
  • Stereoisomerism
  • Stilbenes / administration & dosage
  • Stilbenes / blood*
  • Stilbenes / pharmacokinetics

Substances

  • Stilbenes
  • Caffeine
  • Resveratrol