Solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of boron in plant tissues

Anal Chim Acta. 2007 Jan 23;582(2):214-22. doi: 10.1016/j.aca.2006.09.023. Epub 2006 Sep 19.

Abstract

In this work, the potential of graphite furnace atomic absorption spectrometry for the direct determination of B in plant tissues has been investigated. Three certified reference materials (NIST SRM 1570a spinach leaves, NIST SRM 1573a tomato leaves and BCR CRM 679 white cabbage) were selected for this study, the goal always being to develop a fast procedure that could be robust enough to provide a satisfactory performance for all of them, without any modifications in the conditions applied. The use of a suitable chemical modifier was found to be essential for obtaining a reproducible and sufficiently sensitive signal for boron solutions. In this regard, the performance of the combination of citric acid plus W (added as a permanent modifier) was noteworthy, resulting in well-defined signal profiles, a remarkable analyte stabilization during the pyrolysis step (up to 2100 degrees C) and minimal memory effects. This mixture of modifiers provided a good performance for the direct analysis of solid samples as well, but only if a suitable temperature program, favoring the interaction between the analyte and the modifiers, was used. Thus, such a temperature program, with two pyrolysis steps and the addition of NH(4)NO(3) in order to carry out the in situ sample microdigestion, was optimized. Under these conditions, the peak areas obtained for both solid samples and aqueous standards were comparable. Finally, the analysis of the samples was carried out. In all cases, a good agreement with the certified values was obtained, while R.S.D. values ranged between 6 and 10%. It can be concluded that the method proposed shows significant advantages for the determination of this complicated element in solid samples such as the use of aqueous standards for calibration, a high sample throughput (20 min per sample), a suitable limit of detection (0.3 microg g(-1)) and reduced risk of analyte losses and contamination.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Boron / analysis*
  • Calibration
  • Graphite
  • Plants / chemistry*
  • Reference Standards
  • Reproducibility of Results
  • Spectrophotometry, Atomic / methods*

Substances

  • Graphite
  • Boron