Newer cardiac troponin I assays have similar performance to troponin T in patients with end-stage renal disease

Ann Clin Biochem. 2007 May;44(Pt 3):285-9. doi: 10.1258/000456307780480855.

Abstract

Background: Troponin T is present in the blood of a majority of patients with endstage renal disease (ESRD) undergoing regular dialysis and presence of troponin T is a predictor of adverse outcome in these patients. With several new formulations of troponin I assays available, this study was performed to see whether these newer assays were able to detect troponin I in these patients more effectively than the older assays.

Methods: One hundred and forty-three patients undergoing regular haemodialysis or peritoneal dialysis had plasma collected and troponin T and troponin I measured by a variety of assays.

Results: The newer troponin I assays (Abbott Architect, Bayer Centaur and Beckman Accu-TnI) were able to detect troponin I (>75% of samples) as effectively as the Roche assay was able to detect troponin T, while other troponin I assays had a much lower rate of detection of troponin - DPC Immulite 2000 16% and Abbott AxSYM 35%. However, the troponin T assay had more samples detected at concentrations corresponding to an assay CV of 10% (59% of samples) than did the newer troponin I assays (highest on the Bayer Centaur at 37%).

Conclusions: Newer assays demonstrate that troponin I is present in a similar number of samples as is troponin T, in the blood of patients with dialysis-dependent renal failure, and these newer troponin I assays identify patients at risk of experiencing a cardiac event.

MeSH terms

  • Humans
  • Kidney Failure, Chronic / blood*
  • Kidney Failure, Chronic / therapy
  • Renal Dialysis
  • Sensitivity and Specificity
  • Troponin I / blood*
  • Troponin T / blood*

Substances

  • Troponin I