Impact of implant overloading on the peri-implant bone in inflamed and non-inflamed peri-implant mucosa

Clin Oral Implants Res. 2007 Oct;18(5):601-10. doi: 10.1111/j.1600-0501.2007.01374.x. Epub 2007 Jul 26.

Abstract

Objective: To assess the impact of overloading on peri-implant bone level and the bone-to-implant contact (BIC) in the presence of healthy or inflamed peri-implant tissues.

Materials and methods: Four screw-shaped machined implants were placed bilaterally in the mandible of four beagle dogs and left submerged for 3 months. Prosthetic abutments were connected either in supra-occlusal contact with the opposite teeth (overloaded) or in infra-occlusal position (unloaded). In each dog, cotton floss ligatures were placed unilaterally around abutments to promote plaque accumulation; the contralateral side was brushed three times a week. There were four experimental sites, two implants in each: loaded uninflamed (LU), loaded inflamed (LI), unloaded uninflamed (UU), and unloaded inflamed (UI). Clinical and radiographic parameters were recorded at baseline and every 3 months throughout the observation period. At 12 months, the dogs were sacrificed and histomorphometric analysis was performed.

Results: Implants with ligature-induced peri-implantitis presented high inflammatory indices throughout the observation period. Clinical parameters did not change from baseline for both LU and UU. Loading significantly increased the percentage of BIC (BIC%) (P<0.05) and slightly increased crestal bone resorption, but not apical to the implant neck. Both LI and UI groups showed significant peri-implant bone loss (P<0.01), mostly horizontal on the buccal aspect and angular on the lingual aspect, which exposed implant threads. Loading significantly (P<0.05) increased implant thread exposure due to buccal and lingual vertical bone resorption.

Conclusions: In the presence of uninflamed peri-implant mucosa, overloading of implants in the dog model increased BIC% and slightly reduced marginal bone level. However, resorption did not progress beyond the implant neck. Overloading aggravated the plaque-induced bone resorption when peri-implant inflammation was present.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Alveolar Bone Loss / diagnostic imaging
  • Alveolar Bone Loss / etiology
  • Alveolar Bone Loss / physiopathology
  • Alveolar Process / diagnostic imaging
  • Alveolar Process / physiopathology*
  • Animals
  • Anti-Infective Agents, Local / therapeutic use
  • Chlorhexidine / analogs & derivatives
  • Chlorhexidine / therapeutic use
  • Dental Abutments
  • Dental Implants*
  • Dental Occlusion, Traumatic / complications*
  • Dental Occlusion, Traumatic / physiopathology
  • Dental Plaque / complications
  • Dental Plaque / physiopathology
  • Disease Models, Animal
  • Dogs
  • Mandible / diagnostic imaging
  • Mandible / physiopathology
  • Mandible / surgery
  • Osseointegration / physiology
  • Periodontal Index
  • Periodontitis / complications*
  • Periodontitis / physiopathology
  • Radiography
  • Time Factors
  • Toothbrushing

Substances

  • Anti-Infective Agents, Local
  • Dental Implants
  • chlorhexidine gluconate
  • Chlorhexidine