Abstract
Endovascular closure of high-flow arteriovenous (AV) shunts in intracranial AV malformations or pial fistulas is technically challenging. In this paper, we illustrate two simple methods to occlude large high-flow AV shunts in a controlled manner.
MeSH terms
-
Adult
-
Cerebral Angiography
-
Child
-
Embolization, Therapeutic / methods*
-
Female
-
Humans
-
Intracranial Arteriovenous Malformations / diagnostic imaging
-
Intracranial Arteriovenous Malformations / therapy*
-
Male
-
Tomography, X-Ray Computed