Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
, 2007, 2296-9

LED Power Reduction Trade-Offs for Ambulatory Pulse Oximetry

Affiliations

LED Power Reduction Trade-Offs for Ambulatory Pulse Oximetry

Eduardo Aguilar Peláez et al. Conf Proc IEEE Eng Med Biol Soc.

Abstract

The development of ambulatory arterial pulse oximetry is key to longer term monitoring and treatment of cardiovascular and respiratory conditions. The investigation presented in this paper will assist the designer of an ambulatory pulse oximetry monitor in minimizing the overall LED power consumption (P LED,TOT) levels by analyzing the lowest achievable limit as constrained by the optical components, circuitry implementation and final SpO2 reading accuracy required. LED duty cycle (D LED) reduction and light power (P LED,ON) minimization are proposed as methods to reduce P LED,TOT. Bandwidth and signal quality calculations are carried out in order to determine the required P LED,TOT as a function of the different noise sources.

Similar articles

  • Development of an Implantable Pulse Oximeter
    S Reichelt et al. IEEE Trans Biomed Eng 55 (2 Pt 1), 581-8. PMID 18269993.
    A long-term implantable photoplethysmographic sensor system is proposed. The system employs an elastic cuff which is directly wrapped around an arterial blood vessel. The …
  • An Electronic Patch for Wearable Health Monitoring by Reflectance Pulse Oximetry
    RG Haahr et al. IEEE Trans Biomed Circuits Syst 6 (1), 45-53. PMID 23852744.
    We report the development of an Electronic Patch for wearable health monitoring. The Electronic Patch is a new health monitoring system incorporating biomedical sensors, …
  • A Novel Photodiode for Reflectance Pulse Oximetry in Low-Power Applications
    RG Haahr et al. Conf Proc IEEE Eng Med Biol Soc 2007, 2350-3. PMID 18002464.
    The amount of light collected is crucial for low-power applications of pulse oximetry. In this work a novel ring-shaped backside photodiode has been developed for a weara …
  • The Effect of Motion on Pulse Oximetry and Its Clinical Significance
    MT Petterson et al. Anesth Analg 105 (6 Suppl), S78-84. PMID 18048903. - Review
    Pulse oximetry is an important diagnostic and patient monitoring tool. However, motion can induce considerable error into pulse oximetry accuracy, resulting in loss of da …
  • Pulse Oximetry
    JA Wahr et al. Respir Care Clin N Am 1 (1), 77-105. PMID 9390852. - Review
    Pulse oximetry is a reliable, noninvasive, easy to use means of continuously determining arterial oxygen saturation in virtually any setting. This article details the his …
See all similar articles

Cited by 1 PubMed Central articles

LinkOut - more resources

Feedback