Improvement of left ventricular myocardial short-axis, but not long-axis function or torsion after cardiac resynchronisation therapy: an assessment by two-dimensional speckle tracking

Heart. 2008 Nov;94(11):1464-71. doi: 10.1136/hrt.2007.127498. Epub 2008 Jan 15.

Abstract

Aims: To evaluate whether short-axis function plays a part in determining left ventricular (LV) geometric and functional improvement after cardiac resynchronisation therapy (CRT).

Methods and results: 39 patients who received CRT were enrolled. 2D speckle tracking echocardiography was performed at baseline and three months after CRT to assess mean systolic circumferential (epsilon-circum), radial (epsilon-radial) and longitudinal (epsilon-long) strain and torsion. Responders of reverse remodelling (n = 21) had higher baseline mean epsilon-circum than non-responders (p<0.05), who also had improvement in mean epsilon-circum and mean epsilon-radial (both p<0.05) after CRT. Also, the increase in mean epsilon-circum correlated with increase in ejection fraction (r = 0.57, p<0.001) and decrease in mid-cavity width (r = -0.52, p = 0.001). A baseline mean epsilon-circum of >or=6.5% predicted a gain in ejection fraction >or=5%, with a sensitivity of 73% and a specificity of 71%. The baseline epsilon-long was not different between the two groups, and remained unchanged after CRT. The torsion did not improve in responders, but was worsened in non-responders (p<0.05).

Conclusions: The improvement of LV short-axis function but not long-axis function or torsion contributes to the improvement in LV global function and geometry at three-month follow up. A relatively preserved mean epsilon-circum of >or=6.5% might be useful to predict favourable responses after CRT.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Case-Control Studies
  • Echocardiography
  • Female
  • Heart Failure / diagnostic imaging
  • Heart Failure / physiopathology*
  • Heart Failure / therapy
  • Heart Ventricles / diagnostic imaging
  • Heart Ventricles / physiopathology*
  • Humans
  • Male
  • Middle Aged
  • Pacemaker, Artificial
  • Sensitivity and Specificity
  • Treatment Outcome
  • Ventricular Dysfunction, Left / diagnostic imaging
  • Ventricular Dysfunction, Left / physiopathology*
  • Ventricular Dysfunction, Left / therapy
  • Ventricular Remodeling / physiology*