Improving dose homogeneity in large breasts by IMRT: efficacy and dosimetric accuracy of different techniques

Strahlenther Onkol. 2008 Feb;184(2):86-92. doi: 10.1007/s00066-008-1730-9.

Abstract

Purpose: Evaluation of a simplified intensity-modulated irradiation (IMRT), a three-field (MFT), and a conventional two-tangential-field technique regarding dose homogeneity, target coverage, feasibility and, for the first time, dosimetric reliability in patients with large breasts treated postoperatively for breast cancer on a low-energy linac.

Material and methods: CT datasets of ten patients with relatively large breast volumes treated for breast cancer were selected. For each patient, four treatment plans were created: low-energy conventional (C-LE), high-energy conventional (C-HE), three-field (MFT), and a two-field aperture-based IMRT technique. Apertures for the IMRT and MFT were created with the aid of a three-dimensional dose display. Dosimetric accuracy of each technique was evaluated in an anthropomorphic thorax/breast phantom.

Results: The mean of planning target volumes receiving < 95% or > 105% of the prescribed total dose was reduced from 16.0% to 13.9% to 10.4% to 8.9% in the C-LE, C-HE, MFT, and IMRT plans, respectively. Phantom dose measurements agreed well with the calculated dose within the breast tissue.

Conclusion: Aperture-based IMRT using two tangential incident beam directions, as well as a three-field technique with inverse optimization, provide a better alternative to the standard wedged tangential beams for patients with large breasts treated on low-energy linacs while maintaining the efficiency of the treatment-planning and delivery process.

Publication types

  • Comparative Study
  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Algorithms*
  • Breast / physiopathology
  • Breast Neoplasms / physiopathology*
  • Breast Neoplasms / radiotherapy*
  • Computer Simulation
  • Female
  • Humans
  • Models, Biological*
  • Organ Size
  • Radiometry / methods*
  • Radiotherapy Dosage
  • Radiotherapy Planning, Computer-Assisted / methods*
  • Radiotherapy, Conformal / methods*
  • Relative Biological Effectiveness
  • Reproducibility of Results
  • Scattering, Radiation
  • Sensitivity and Specificity