Reductions of E. coli, echovirus type 12 and bacteriophages in an intermittently operated household-scale slow sand filter
- PMID: 18281076
- DOI: 10.1016/j.watres.2008.01.016
Reductions of E. coli, echovirus type 12 and bacteriophages in an intermittently operated household-scale slow sand filter
Abstract
Point-of-use (POU) drinking water treatment technology enables those without access to safe water sources to improve the quality of their water by treating it in the home. One of the most promising emerging POU technologies is the biosand filter (BSF), a household-scale, intermittently operated slow sand filter. Over 500,000 people in developing countries currently use the filters to treat their drinking water. However, despite this successful implementation, there has been almost no systematic, process engineering research to substantiate the effectiveness of the BSF or to optimize its design and operation. The major objectives of this research were to: (1) gain an understanding of the hydraulic flow condition within the filter (2) characterize the ability of the BSF to reduce the concentration of enteric bacteria and viruses in water and (3) gain insight into the key parameters of filter operation and their effects on filter performance. Three 6-8 week microbial challenge experiments are reported herein in which local surface water was seeded with E. coli, echovirus type 12 and bacteriophages (MS2 and PRD-1) and charged to the filter daily. Tracer tests indicate that the BSF operated at hydraulic conditions closely resembling plug flow. The performance of the filter in reducing microbial concentrations was highly dependent upon (1) filter ripening over weeks of operation and (2) the daily volume charged to the filter. BSF performance was best when less than one pore volume (18.3-L in the filter design studied) was charged to the filter per day and this has important implications for filter design and operation. Enhanced filter performance due to ripening was generally observed after roughly 30 days. Reductions of E. coli B ranged from 0.3 log10 (50%) to 4 log10, with geometric mean reductions after at least 30 days of operation of 1.9 log10. Echovirus 12 reductions were comparable to those for E. coli B with a range of 1 log10 to >3 log10 and mean reductions after 30 days of 2.1 log10. Bacteriophage reductions were much lower, ranging from zero to 1.3 log10 (95%) with mean reductions of only 0.5 log10 (70%). These data indicate that virus reduction by BSF may differ substantially depending upon the specific viral agent.
Similar articles
-
Investigation of E. coli and Virus Reductions Using Replicate, Bench-Scale Biosand Filter Columns and Two Filter Media.Int J Environ Res Public Health. 2015 Aug 25;12(9):10276-99. doi: 10.3390/ijerph120910276. Int J Environ Res Public Health. 2015. PMID: 26308036 Free PMC article.
-
Intermittent versus continuous operation of biosand filters.Water Res. 2014 Feb 1;49:1-10. doi: 10.1016/j.watres.2013.11.011. Epub 2013 Nov 19. Water Res. 2014. PMID: 24316177
-
Bacterial, viral and turbidity removal by intermittent slow sand filtration for household use in developing countries: experimental investigation and modeling.Water Res. 2011 Nov 15;45(18):6227-39. doi: 10.1016/j.watres.2011.09.022. Epub 2011 Sep 22. Water Res. 2011. PMID: 21974872
-
Multi-scale Cryptosporidium/sand interactions in water treatment.Water Res. 2006 Oct;40(18):3315-31. doi: 10.1016/j.watres.2006.07.036. Epub 2006 Sep 18. Water Res. 2006. PMID: 16979211 Review.
-
A critical overview of household slow sand filters for water treatment.Water Res. 2022 Jan 1;208:117870. doi: 10.1016/j.watres.2021.117870. Epub 2021 Nov 16. Water Res. 2022. PMID: 34823084 Review.
Cited by
-
Evaluation of Chitosans as Coagulants-Flocculants to Improve Sand Filtration for Drinking Water Treatment.Int J Mol Sci. 2023 Jan 9;24(2):1295. doi: 10.3390/ijms24021295. Int J Mol Sci. 2023. PMID: 36674812 Free PMC article.
-
Slow Sand Filters for the 21st Century: A Review.Int J Environ Res Public Health. 2023 Jan 5;20(2):1019. doi: 10.3390/ijerph20021019. Int J Environ Res Public Health. 2023. PMID: 36673775 Free PMC article. Review.
-
Electrochemical Disinfection in Water and Wastewater Treatment: Identifying Impacts of Water Quality and Operating Conditions on Performance.Environ Sci Technol. 2021 Mar 16;55(6):3470-3482. doi: 10.1021/acs.est.0c06254. Epub 2021 Feb 22. Environ Sci Technol. 2021. PMID: 33616403 Free PMC article. Review.
-
Occurrence, fates and potential treatment approaches for removal of viruses from wastewater: A review with emphasis on SARS-CoV-2.J Environ Chem Eng. 2020 Oct;8(5):104429. doi: 10.1016/j.jece.2020.104429. Epub 2020 Sep 2. J Environ Chem Eng. 2020. PMID: 32895629 Free PMC article. Review.
-
Linking Decision Theory and Quantitative Microbial Risk Assessment: Tradeoffs Between Compliance and Efficacy for Waterborne Disease Interventions.Risk Anal. 2019 Oct;39(10):2214-2226. doi: 10.1111/risa.13381. Epub 2019 Sep 17. Risk Anal. 2019. PMID: 31529800 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous