Determining kinetics and affinities of protein interactions using a parallel real-time label-free biosensor, the Octet
- PMID: 18405656
- DOI: 10.1016/j.ab.2008.03.035
Determining kinetics and affinities of protein interactions using a parallel real-time label-free biosensor, the Octet
Abstract
ForteBio's Octet optical biosensor harnesses biolayer interferometry to detect and quantify molecular interactions using disposable fiber-optic biosensors that address samples from an open shaking microplate without any microfluidics. We recruited a monoclonal antibody against a panel of peptides to compare the Octet directly with Biacore's well-established 3000 platform and Bio-Rad's recently launched ProteOn XPR36 array system, which use surface plasmon resonance (SPR) to detect the binding of one analyte over four surfaces and six analytes over six surfaces, respectively. A sink method was used to prevent analyte from rebinding the ligand-coated Octet tips and enabled us to extract accurate kinetic rate constants, as judged by their close agreement with those determined by SPR. Although the Octet is not sensitive enough to detect the binding of small molecules directly, it can access their affinities indirectly via solution competition experiments. We conducted similar experiments on the SPR instruments to validate these measurements. The Octet is emerging as a versatile complement to other more sophisticated biosensors, and the ProteOn provides high-quality data near the sensitivity of Biacore but in a more multiplexed format. Our results provide a benchmark for assessing the performance of the above-mentioned sensors.
Similar articles
-
Exploring blocking assays using Octet, ProteOn, and Biacore biosensors.Anal Biochem. 2009 Mar 15;386(2):172-80. doi: 10.1016/j.ab.2008.11.038. Epub 2008 Dec 7. Anal Biochem. 2009. PMID: 19111520
-
Expanding the ProteOn XPR36 biosensor into a 36-ligand array expedites protein interaction analysis.Anal Biochem. 2011 Apr 1;411(1):139-51. doi: 10.1016/j.ab.2010.12.020. Epub 2010 Dec 17. Anal Biochem. 2011. PMID: 21168382
-
Determination of High-affinity Antibody-antigen Binding Kinetics Using Four Biosensor Platforms.J Vis Exp. 2017 Apr 17;(122):55659. doi: 10.3791/55659. J Vis Exp. 2017. PMID: 28448040 Free PMC article.
-
Surface plasmon resonance biosensing.Methods Mol Biol. 2009;503:65-88. doi: 10.1007/978-1-60327-567-5_5. Methods Mol Biol. 2009. PMID: 19151937 Review.
-
Looking towards label-free biomolecular interaction analysis in a high-throughput format: a review of new surface plasmon resonance technologies.Curr Opin Biotechnol. 2006 Aug;17(4):400-5. doi: 10.1016/j.copbio.2006.06.012. Epub 2006 Jul 11. Curr Opin Biotechnol. 2006. PMID: 16837183 Review.
Cited by
-
2LTRZFP Interacts Specifically to HIV-1 DNA without Off-Target Effects as Determined by Biolayer Interferometry.Biosensors (Basel). 2021 Mar 8;11(3):76. doi: 10.3390/bios11030076. Biosensors (Basel). 2021. PMID: 33800287 Free PMC article.
-
High throughput solution-based measurement of antibody-antigen affinity and epitope binning.MAbs. 2013 Mar-Apr;5(2):270-8. doi: 10.4161/mabs.23049. MAbs. 2013. PMID: 23575269 Free PMC article.
-
Expression of high-affinity human antibody fragments in bacteria.Nat Protoc. 2012 Feb 2;7(2):364-73. doi: 10.1038/nprot.2011.448. Nat Protoc. 2012. PMID: 22301775
-
Immunoaffinity monoliths for multiplexed extraction of preterm birth biomarkers from human blood serum in 3D printed microfluidic devices.Analyst. 2022 Feb 14;147(4):734-743. doi: 10.1039/d1an01365c. Analyst. 2022. PMID: 35103723 Free PMC article.
-
Poxvirus proteomics and virus-host protein interactions.Microbiol Mol Biol Rev. 2009 Dec;73(4):730-49. doi: 10.1128/MMBR.00026-09. Microbiol Mol Biol Rev. 2009. PMID: 19946139 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources