Calculation of normal tissue complication probability and dose-volume histogram reduction schemes for tissues with a critical element architecture

Radiother Oncol. 1991 Mar;20(3):166-76. doi: 10.1016/0167-8140(91)90093-v.

Abstract

We investigate a model of normal tissue complication probability for tissues that may be represented by a critical element architecture. We derive formulas for complication probability that apply to both a partial volume irradiation and to an arbitrary inhomogeneous dose distribution. The dose-volume isoeffect relationship which is a consequence of a critical element architecture is discussed and compared to the empirical power law relationship. A dose-volume histogram reduction scheme for a "pure" critical element model is derived. In addition, a point-based algorithm which does not require precomputation of a dose-volume histogram is derived. The existing published dose-volume histogram reduction algorithms are analyzed. We show that the existing algorithms, developed empirically without an explicit biophysical model, have a close relationship to the critical element model at low levels of complication probability. However, we also show that they have aspects which are not compatible with a critical element model and we propose a modification to one of them to circumvent its restriction to low complication probabilities.

Publication types

  • Research Support, U.S. Gov't, P.H.S.

MeSH terms

  • Algorithms
  • Dose-Response Relationship, Radiation*
  • Humans
  • Mathematical Computing*
  • Models, Statistical*
  • Probability*
  • Radiation Injuries*