Comparison of temperature readings from a percutaneous thermal sensing microchip with temperature readings from a digital rectal thermometer in equids
- PMID: 18710319
- DOI: 10.2460/javma.233.4.613
Comparison of temperature readings from a percutaneous thermal sensing microchip with temperature readings from a digital rectal thermometer in equids
Abstract
Objective: To compare temperature readings from an implantable percutaneous thermal sensing microchip with temperature readings from a digital rectal thermometer, to identify factors that affect microchip readings, and to estimate the sensitivity and specificity of the microchip for fever detection.
Design: Prospective study.
Animals: 52 Welsh pony foals that were 6 to 10 months old and 30 Quarter Horses that were 2 years old.
Procedures: Data were collected in summer, winter, and fall in groups 1 (n = 23 ponies), 2 (29 ponies), and 3 (30 Quarter Horses), respectively. Temperature readings from a digital rectal thermometer and a percutaneous thermal sensing microchip as well as ambient temperature were recorded daily for 17, 23, and 19 days in groups 1 through 3, respectively. Effects of ambient temperature and rectal temperature on thermal sensor readings were estimated. Sensitivity and specificity of the thermal sensor for detection of fever (rectal temperature, >or= 38.9 degrees C [102 degrees F]) were estimated separately for data collection at ambient temperatures <or= 15.6 degrees C (60 degrees F) and > 15.6 degrees C.
Results: Mean ambient temperatures were 29.0 degrees C (84.2 degrees F), -2.7 degrees C (27.1 degrees F), and 10.4 degrees C (50.8 degrees F) for groups 1 through 3, respectively. Thermal sensor readings varied with ambient temperature and rectal temperature. Rectal temperatures ranged from 36.2 degrees to 41.7 degrees C (97.2 degrees to 107 degrees F), whereas thermal sensor temperature readings ranged from 23.9 degrees (75 degrees F) to 42.2 degrees C (75 degrees to 108 degrees F). Sensitivity for fever detection was 87.4%, 53.3%, and 58.3% in groups 1 to 3, respectively.
Conclusions and clinical relevance: The thermal sensor appeared to have potential use for initial screening of body temperature in equids at ambient temperatures > 15.6 degrees C.
Similar articles
-
Comparison of three methods of temperature measurement in hypothermic, euthermic, and hyperthermic dogs.J Am Vet Med Assoc. 2007 Jun 15;230(12):1841-8. doi: 10.2460/javma.230.12.1841. J Am Vet Med Assoc. 2007. PMID: 17571987 Clinical Trial.
-
Accuracy of infrared ear thermometry and traditional temperature methods in young children.Heart Lung. 1994 May-Jun;23(3):181-95. Heart Lung. 1994. PMID: 8039988 Clinical Trial.
-
Factors affecting rectal temperature measurement using commonly available digital thermometers.Res Vet Sci. 2012 Feb;92(1):121-3. doi: 10.1016/j.rvsc.2010.10.027. Epub 2010 Dec 13. Res Vet Sci. 2012. PMID: 21147490
-
[Body temperature measurement in daily practice].Arch Pediatr. 2005 Aug;12(8):1292-300. doi: 10.1016/j.arcped.2005.01.034. Arch Pediatr. 2005. PMID: 15993044 Review. French.
-
Body temperature variability (Part 1): a review of the history of body temperature and its variability due to site selection, biological rhythms, fitness, and aging.Altern Med Rev. 2006 Dec;11(4):278-93. Altern Med Rev. 2006. PMID: 17176167 Review.
Cited by
-
Thermoregulation during Field Exercise in Horses Using Skin Temperature Monitoring.Animals (Basel). 2023 Dec 30;14(1):136. doi: 10.3390/ani14010136. Animals (Basel). 2023. PMID: 38200867 Free PMC article.
-
Heat stress in horses: a literature review.Int J Biometeorol. 2023 Jun;67(6):957-973. doi: 10.1007/s00484-023-02467-7. Epub 2023 Apr 15. Int J Biometeorol. 2023. PMID: 37060454 Free PMC article. Review.
-
Is Continuous Monitoring of Skin Surface Temperature a Reliable Proxy to Assess the Thermoregulatory Response in Endurance Horses During Field Exercise?Front Vet Sci. 2022 May 27;9:894146. doi: 10.3389/fvets.2022.894146. eCollection 2022. Front Vet Sci. 2022. PMID: 35711810 Free PMC article.
-
The Use of Percutaneous Thermal Sensing Microchips to Measure Body Temperature in Horses during and after Exercise Using Three Different Cool-Down Methods.Animals (Basel). 2022 May 14;12(10):1267. doi: 10.3390/ani12101267. Animals (Basel). 2022. PMID: 35625113 Free PMC article.
-
The Use of Percutaneous Thermal Sensing Microchips for Body Temperature Measurements in Horses Prior to, during and after Treadmill Exercise.Animals (Basel). 2020 Dec 2;10(12):2274. doi: 10.3390/ani10122274. Animals (Basel). 2020. PMID: 33276500 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical