Usefulness of rCBF analysis in diagnosing Parkinson's disease: supplemental role with MIBG myocardial scintigraphy

Ann Nucl Med. 2008 Aug;22(7):557-64. doi: 10.1007/s12149-008-0156-x. Epub 2008 Aug 29.

Abstract

(123)I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy is a useful tool for differentiating idiopathic Parkinson's disease (PD) from parkinsonism (PS) caused by other disorders. However, cardiac MIBG uptake is affected by various causes. Alternatively, hypoperfusion in the occipital lobe of PD is reported recently.

Objective: The objective is to clarify the correlation between regional cerebral blood flow (rCBF) alteration and cardiac MIBG uptake in PD. In addition, we examined whether additional brain perfusion analysis improved the differential diagnostic ability for PD from PS when compared with MIBG scintigraphy alone.

Methods: Forty-nine patients with PD (27 mild groups: Hoehn and Yahr stages I, II; 22 severe groups: Hoehn and Yahr stages III, IV) and 28 patients with PS participated. We compared absolute rCBF values between PD and PS. In addition, we determined correlation between MIBG parameters and each rCBF value. Finally, we compared the diagnostic ability for the differentiation of PD from PS between two diagnostic criteria, each MIBG index abnormality alone [heart-to-mediastinum ratio, H/M (E) < 1.9, H/E (D) < 1.7, washout rate > 40%] and each MIBG index abnormality or occipital lobe hypoperfusion (<36 ml/100 g per min).

Results: Absolute rCBF value of occipital lobe was significantly lower in severe PD as compared with PS or mild PD. In the correlation analysis, rCBF of occipital lobe correlated positively with MIBG parameters (H/M). Regarding the diagnostic ability, sensitivity improved by accounting for occipital hypoperfusion as compared with MIBG indices alone. In contrast, neither specificity nor accuracy improved by adding occipital lobe analysis.

Conclusions: MIBG parameters (H/M) correlated positively with occipital hypoperfusion in PD. In the differential diagnosis between PD and PS, although its usefulness might be limited, analysis of rCBF in the occipital lobe added to (123)I-MIBG myocardial imaging can be recommended.

MeSH terms

  • 3-Iodobenzylguanidine / pharmacokinetics
  • Aged
  • Cerebrovascular Circulation
  • Cross-Sectional Studies
  • Diagnosis, Differential
  • Female
  • Heart / diagnostic imaging*
  • Heart / physiopathology*
  • Humans
  • Lewy Body Disease / diagnostic imaging*
  • Lewy Body Disease / physiopathology
  • Male
  • Middle Aged
  • Occipital Lobe / blood supply*
  • Occipital Lobe / diagnostic imaging
  • Occipital Lobe / physiopathology*
  • Parkinson Disease / diagnostic imaging*
  • Parkinson Disease / physiopathology
  • Parkinson Disease, Secondary / diagnostic imaging*
  • Parkinson Disease, Secondary / physiopathology
  • Radiopharmaceuticals / pharmacokinetics
  • Sensitivity and Specificity
  • Technetium Tc 99m Exametazime / pharmacokinetics
  • Tomography, Emission-Computed, Single-Photon

Substances

  • Radiopharmaceuticals
  • 3-Iodobenzylguanidine
  • Technetium Tc 99m Exametazime