. 2008 Nov 27:8:12.
doi: 10.1186/1472-6890-8-12.

Derivation and internal validation of an equation for albumin-adjusted calcium

Affiliations

Derivation and internal validation of an equation for albumin-adjusted calcium

Matthew T James et al. BMC Clin Pathol. .

Abstract

Background: Previously published equations to adjust calcium for albumin concentration may vary depending on factors such as the type of reagents used. Albumin-adjusted calcium equations derived from laboratories using the bromocresol purple (BCP) albumin binding reagent have not been described.

Methods: The linear regression equation for the binding of calcium and BCP-albumin was derived in a cohort of 4613 outpatients, and the albumin-adjusted calcium equation was internally validated in a separate cohort of 1538 subjects. The performance of this equation was compared with a previously published equation (adjusted [Ca](mmol/L) = total [Ca](mmol/L) + 0.02 (40 - [albumin] (g/L)) in 343 subjects with albumin < 33 g/L (below reference range).

Results: The local adjustment equation was expressed by the relationship; adjusted [Ca](mmol/L) = total [Ca](mmol/L) + 0.012 (39.9 - [albumin](g/L)). The equation showed evidence of good internal validity (shrinkage value of adjusted r2 = -0.0059). Classification of calcium status differed between the two equations in 47 of 343 subjects with low serum albumin (weighted kappa = 0.46; moderate agreement).

Conclusion: A locally derived and internally validated albumin-adjusted calcium equation differed from previously published equations and resulted in important differences in classification of calcium status in hypoalbuminemia patients. Individual laboratories should determine their own linear regression equation for calcium on albumin rather than relying on published formulas.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Linear regression relationship of serum total calcium on albumin derived from a cohort of 4613 patients with simultaneous total calcium and BCP-albumin measurements.

Similar articles

Cited by

References

    1. Payne R, Little A, Williams R, Milner J. Interpretation of serum calcium in patients with abnormal serum proteins. Br Med J. 1973;4:643–646. - PMC - PubMed
    1. Orell D. Albumin as an aid to the interpretation of serum calcium. Clin Chim Acta. 1971;35:483–489. doi: 10.1016/0009-8981(71)90224-5. - DOI - PubMed
    1. Berry E, Gupta M, Turner S, Burns R. Variations in plasma calcium with induced changes in plasma specific gravity, total protein and albumin. Br Med J. 1973;4:640–643. - PMC - PubMed
    1. Payne R, Carver M, Morgan D. Interpretation of serum total calcium: effects of adjustment for albumin concentration on frequency of abnormal values and on detection of change in the individual. J of Clin Path. 1979;32:56–60. doi: 10.1136/jcp.32.1.56. - DOI - PMC - PubMed
    1. Ashby J, Wright D, Rinsler M. The adjusted serum calcium concept – a reappraisal. Ann Clin Biochem. 1986;23:533–537. - PubMed