Modified orthostatic load for spectral analysis of short-term heart rate variability improves the sensitivity of autonomic dysfunction assessment

J Diabetes Complications. 2010 Jan-Feb;24(1):48-54. doi: 10.1016/j.jdiacomp.2008.10.003. Epub 2008 Dec 5.

Abstract

Aim: To evaluate the impact of orthostatic load for sensitivity of short-term spectral analysis of heart rate variability (HRV) assessment of potential early autonomic dysfunction in diabetes mellitus.

Methods: Comparison of results of short-term time- and frequency-domain analysis of HRV during single positions and during modified orthostatic load (supine 1-standing-supine 2, each position 300 s) in diabetic subjects with good glycemic control (n=80, age 38+/-14, diabetes duration 16+/-10 years) and without autonomic neuropathy as assessed by a standard bedside reflex test battery, and in nondiabetic controls (n=150, age 40+/-13 years).

Results: None of the short-term frequency-domain parameters [absolute and logarithmic (LN) values of spectral powers in total- (TF), low- (LF), and high-frequency (HF) bands and its centroid frequencies] as obtained in single positions "supine" or "standing" revealed a significant difference between well-controlled patients and healthy controls (P>.3). However, during modified orthostatic load, significant differences in DeltaLN TF((supine 1-supine 2)) and in DeltaLN LF((supine 1-supine 2)) as well as in DeltaLN LF((standing-supine 2)) values between diabetic and healthy subjects were recorded [-0.2+/-0.5 vs. -0.1+/-0.4 LN (ms(2)), P=.05; -0.3+/-0.8 vs. 0.1+/-0.7 LN (ms(2)), P=.001 and 0.2+/-1.0 vs. 0.4+/-0.9 LN (ms(2)), P=.05, respectively] with insignificant intergroup differences in related centroid frequencies. This finding suggests a delayed recovery of LF spectral power in diabetic subjects after orthostatic challenge.

Conclusions: When compared with single position measurements, the modified orthostatic load protocol improves the sensitivity of short-term HRV examination. In well-controlled diabetic subjects without cardiovascular autonomic neuropathy (as excluded by standard cardiovascular reflex testing), the delayed recovery of LF band spectral power after orthostatic load with standing up indicates diminished parasympathetic activation.

Publication types

  • Comparative Study

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Autonomic Nervous System / physiopathology*
  • Diabetes Mellitus / physiopathology*
  • Diabetic Neuropathies / diagnosis*
  • Diabetic Neuropathies / physiopathology
  • Diagnostic Techniques, Cardiovascular*
  • Diagnostic Techniques, Neurological
  • Early Diagnosis
  • Female
  • Fourier Analysis
  • Glycated Hemoglobin / analysis
  • Heart Rate*
  • Humans
  • Hypotension, Orthostatic / diagnosis
  • Male
  • Middle Aged
  • Young Adult

Substances

  • Glycated Hemoglobin A
  • hemoglobin A1c protein, human