Development of electrochemical sensors for nano scale Tb(III) ion determination based on pendant macrocyclic ligands

Anal Chim Acta. 2009 Feb 2;633(1):109-18. doi: 10.1016/j.aca.2008.11.029. Epub 2008 Nov 20.

Abstract

The two macrocyclic pendant ligands 3,4,5:12,13,14-dipyridine-2,6,11,15-tetramethyl-1,7,10,16-tetramethylacrylate-1,4,7,10,13,16-hexaazacyclooctadeca-3,13-di ene (L(1)) and 3,4,5:12,13,14-dipyridine-2,6,11,15-tetramethyl-1,7,10,16-tetra(2-cyano ethane)-1,4,7,10,13,16-hexaazacyclooctadeca-3,13-diene (L(2)) have been synthesized and explored as neutral ionophores for preparing poly(vinylchloride) (PVC) based membrane sensors selective to Tb(III) ions. Effects of various plasticizers and anion excluders were studied in detail and improved performance was observed. The best performance was obtained for the membrane sensor having a composition of L(1): PVC:1-CN:NaTPB in the ratio of 6: 32: 58: 4 (w/w; mg). The performance of the membrane based on L(1) was compared with polymeric membrane electrode (PME) as well as with coated graphite electrode (CGE). The electrodes exhibit Nernstian slope for Tb(3+) ions with limits of detection of 3.4 x 10(-8)mol L(-1) for PME and 5.7 x 10(-9)mol L(-1) for CGE. The response time for PME and CGE was found to be 10s and 8s, respectively. The potentiometric responses are independent of the pH of the test solution in the pH range 3.0-7.5 for PME and 2.0-8.5 for CGE. The CGE has found to work satisfactorily in partially non-aqueous media upto 30% (v/v) content of methanol, ethanol and 20% (v/v) content of acetonitrile and could be used for a period of 5 months. The CGE was used as indicator electrode in the potentiometric titration of Tb(3+) ions with EDTA and in determination of fluoride ions in various samples. It can also be used in direct determination of Tb(3+) ions in tap water and various binary mixtures with quantitative results.

Publication types

  • Evaluation Study

MeSH terms

  • Calibration
  • Edetic Acid / chemistry
  • Electrochemistry / instrumentation
  • Electrochemistry / methods*
  • Electrodes
  • Fluorides / chemistry
  • Graphite / chemistry
  • Hydrogen-Ion Concentration
  • Ionophores / chemistry
  • Ions / chemistry
  • Ligands
  • Macrocyclic Compounds / chemical synthesis*
  • Macrocyclic Compounds / chemistry
  • Membranes, Artificial
  • Plasticizers / chemistry
  • Polyvinyl Chloride / chemical synthesis
  • Polyvinyl Chloride / chemistry
  • Sensitivity and Specificity
  • Solvents / chemistry
  • Surface-Active Agents / chemistry
  • Terbium / analysis*
  • Terbium / chemistry

Substances

  • Ionophores
  • Ions
  • Ligands
  • Macrocyclic Compounds
  • Membranes, Artificial
  • Plasticizers
  • Solvents
  • Surface-Active Agents
  • Terbium
  • Graphite
  • terbium chloride
  • Polyvinyl Chloride
  • Edetic Acid
  • Fluorides