A quality initiative to decrease pathology specimen-labeling errors using radiofrequency identification in a high-volume endoscopy center
- PMID: 19259073
- DOI: 10.1038/ajg.2008.170
A quality initiative to decrease pathology specimen-labeling errors using radiofrequency identification in a high-volume endoscopy center
Abstract
Objectives: Our institution has had problems with mislabeling of tissue specimens in our gastrointestinal and colorectal surgery endoscopy units. Most labeling errors have been due to either the wrong patient label or no label being affixed to a specimen bottle. As a result, an initiative was created to reduce the number of specimen-labeling errors. This initiative involved the application of radiofrequency identification (RFID) technology to specimen bottles, moving to a paperless pathology requisition system and confirmation of the correct site and correct patient by both the endoscopy nursing staff and the endoscopist for each specimen bottle.
Methods: We reviewed the number of specimen-labeling errors from our endoscopy unit for the first 3 months of 2007, before the implementation of the initiative, and for the first 3 months of 2008, 6 months after the initiation of RFID specimen labeling with paperless requisition and two-provider confirmation of correct site, correct patient specimen labeling. The RFID system we used was an off-the-shelf 3M (St. Paul, MN) Library Sciences RFID system modified and installed for our purposes. Specimen-labeling errors were categorized as Class 1 (only typographical with no potential clinical consequences), Class 2 (minor error, unlikely to have clinical consequences) or Class 3 (significant error that has the potential to detrimentally impact patient care). The Fischer's exact test was used to compare the rate of specimen-bottle labeling errors before and after the initiation of this new system.
Results: In the first 3 months of 2007, our endoscopy unit sent 8,231 specimen bottles to our pathology laboratory for evaluation; 8,539 bottles were sent in the first 3 months of 2008. There were 646 (7.85%) Class 1 errors in the first quarter of 2007 and 35 (0.41%) in the first quarter of 2008 (P<0.001). There were 112 (1.36%) Class 2 errors in the first quarter of 2007 and 10 (0.12%) in the first quarter of 2008 (P<0.001). Finally, in the first quarter of 2007 there were seven (0.09%) Class 3 errors and in the first quarter of 2008, there were two (0.02%) Class 3 errors. However, with the new system in place, both Class 3 errors in the first quarter of 2008 were recognized and corrected before the processing of the specimens in the pathology laboratory (P=0.001).
Conclusions: These data confirm that the initiation of a new specimen-labeling system that uses RFID technology, a paperless requisition process, and confirmation of the correct site and correct patient by two health-care providers significantly decreased specimen-labeling errors at every level in a high-volume endoscopy center.
Similar articles
-
Surgical specimen identification errors: a new measure of quality in surgical care.Surgery. 2007 Apr;141(4):450-5. doi: 10.1016/j.surg.2006.08.018. Epub 2007 Jan 24. Surgery. 2007. PMID: 17383521
-
Specimen labeling errors in surgical pathology: an 18-month experience.Am J Clin Pathol. 2010 Sep;134(3):466-70. doi: 10.1309/AJCPHLQHJ0S3DFJK. Am J Clin Pathol. 2010. PMID: 20716804
-
Identification errors in pathology and laboratory medicine.Clin Lab Med. 2004 Dec;24(4):979-96, vii. doi: 10.1016/j.cll.2004.05.013. Clin Lab Med. 2004. PMID: 15555752 Review.
-
Reduction in specimen labeling errors after implementation of a positive patient identification system in phlebotomy.Am J Clin Pathol. 2010 Jun;133(6):870-7. doi: 10.1309/AJCPC95YYMSLLRCX. Am J Clin Pathol. 2010. PMID: 20472844
-
The laboratory and patient safety.Clin Lab Med. 2007 Dec;27(4):909-30, viii-ix. doi: 10.1016/j.cll.2007.07.002. Clin Lab Med. 2007. PMID: 17950905 Review.
Cited by
-
Evaluation of errors related to surgical pathology specimens of different hospital departments with a patient safety approach: a case study in Iran.Patient Saf Surg. 2023 Apr 18;17(1):8. doi: 10.1186/s13037-023-00360-1. Patient Saf Surg. 2023. PMID: 37072837 Free PMC article.
-
Design, Development, and Evaluation of the Blood Collection Management Workstation.Risk Manag Healthc Policy. 2022 Oct 31;15:2015-2022. doi: 10.2147/RMHP.S384866. eCollection 2022. Risk Manag Healthc Policy. 2022. PMID: 36341474 Free PMC article.
-
RFID analytics for hospital ward management.Flex Serv Manuf J. 2016;28(4):593-616. doi: 10.1007/s10696-015-9230-6. Epub 2015 Oct 23. Flex Serv Manuf J. 2016. PMID: 32288935 Free PMC article.
-
Electronic p-Chip-Based System for Identification of Glass Slides and Tissue Cassettes in Histopathology Laboratories.J Pathol Inform. 2018 Apr 2;9:9. doi: 10.4103/jpi.jpi_64_17. eCollection 2018. J Pathol Inform. 2018. PMID: 29692946 Free PMC article.
-
Radio Frequency Identification (RFID) technology and patient safety.J Res Med Sci. 2013 Sep;18(9):809-13. J Res Med Sci. 2013. PMID: 24381626 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials