A correlation found between contact allergy to stent material and restenosis of the coronary arteries

Contact Dermatitis. 2009 Mar;60(3):158-64. doi: 10.1111/j.1600-0536.2008.01502.x.

Abstract

Background: Metallic implants, stents, are increasingly being used especially in patients with stenosis of the cardiac vessels. Ten to thirty per cent of the patients suffer from restenosis regardless of aetiology. We have shown increased frequency of contact allergy to stent metals in stented patients.

Objectives: To we evaluate whether contact allergy to stent material is a risk factor for restenosis.

Methods: Patients with stainless steel stents, with or without gold plating, were epicutaneously tested and answered a questionnaire. The restenosis rate was evaluated.

Results: We found a correlation between contact allergy to gold, gold stent, and restenosis (OR 2.3, CI 1.0-5.1, P = 0.04). The risk for restenosis was threefold increased when the patient was gold allergic and stented with a gold-plated stent. An increased degree of chest pain in gold-allergic patients stented with gold-plated stent was found.

Conclusions: We found a correlation between contact allergy to gold, gold-stent, and restenosis. It may be of importance to consider contact allergy when developing new materials for stenting.

Publication types

  • Comparative Study

MeSH terms

  • Angioplasty, Balloon, Coronary
  • Chi-Square Distribution
  • Coronary Artery Disease / therapy
  • Coronary Restenosis / epidemiology
  • Coronary Restenosis / etiology*
  • Dermatitis, Allergic Contact / diagnosis
  • Dermatitis, Allergic Contact / epidemiology
  • Dermatitis, Allergic Contact / etiology*
  • Female
  • Gold / adverse effects*
  • Humans
  • Male
  • Recurrence
  • Risk Factors
  • Stainless Steel / adverse effects*
  • Stents / adverse effects*
  • Sweden

Substances

  • Stainless Steel
  • Gold