Limits of temporal pitch in cochlear implants

J Acoust Soc Am. 2009 Mar;125(3):1649-57. doi: 10.1121/1.3068457.

Abstract

A common finding in the cochlear implant literature is that the upper limit of rate discrimination on a single channel is about 300 pps. The present study investigated rate discrimination using a procedure in which, in each block of two-interval trials, the standard could have one of the five baseline rates (100, 200, 300, 400, and 500 pps) and the signal rate was a given percentage higher than the standard. Eight Med-El C40+ subjects took part. The pattern of results was different than those reported previously: six Med-El subjects performed better at medium rates (200-300 pps) compared to both lower (100 pps) and higher (400-500 pps) rates. A similar pattern of results was obtained both with the method of constant stimuli and for 5000-pps pulse trains amplitude modulated at rates between 100 and 500 Hz. Compared to an unmatched group of eight Nucleus CI24 listeners tested using a similar paradigm and stimuli, Med-El subjects performed significantly better at 300 pps and higher but slightly worse at 100 pps. These results are discussed in relation to evidence on the limits of temporal pitch at low and high rates in normal-hearing listeners.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Cochlear Implants*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Pitch Perception*
  • Time Perception*