Chlorhexidine-impregnated sponges and less frequent dressing changes for prevention of catheter-related infections in critically ill adults: a randomized controlled trial
- PMID: 19318651
- DOI: 10.1001/jama.2009.376
Chlorhexidine-impregnated sponges and less frequent dressing changes for prevention of catheter-related infections in critically ill adults: a randomized controlled trial
Abstract
Context: Use of a chlorhexidine gluconate-impregnated sponge (CHGIS) in intravascular catheter dressings may reduce catheter-related infections (CRIs). Changing catheter dressings every 3 days may be more frequent than necessary.
Objective: To assess superiority of CHGIS dressings regarding the rate of major CRIs (clinical sepsis with or without bloodstream infection) and noninferiority (less than 3% colonization-rate increase) of 7-day vs 3-day dressing changes.
Design, setting, and patients: Assessor-blind, 2 x 2 factorial, randomized controlled trial conducted from December 2006 through June 2008 and recruiting patients from 7 intensive care units in 3 university and 2 general hospitals in France. Patients were adults (>18 years) expected to require an arterial catheter, central-vein catheter, or both inserted for 48 hours or longer.
Interventions: Use of CHGIS vs standard dressings (controls). Scheduled change of unsoiled adherent dressings every 3 vs every 7 days, with immediate change of any soiled or leaking dressings.
Main outcome measures: Major CRIs for comparison of CHGIS vs control dressings; colonization rate for comparison of 3- vs 7-day dressing changes.
Results: Of 2095 eligible patients, 1636 (3778 catheters, 28,931 catheter-days) could be evaluated. The median duration of catheter insertion was 6 (interquartile range [IQR], 4-10) days. There was no interaction between the interventions. Use of CHGIS dressings decreased the rates of major CRIs (10/1953 [0.5%], 0.6 per 1000 catheter-days vs 19/1825 [1.1%], 1.4 per 1000 catheter-days; hazard ratio [HR], 0.39 [95% confidence interval {CI}, 0.17-0.93]; P = .03) and catheter-related bloodstream infections (6/1953 catheters, 0.40 per 1000 catheter-days vs 17/1825 catheters, 1.3 per 1000 catheter-days; HR, 0.24 [95% CI, 0.09-0.65]). Use of CHGIS dressings was not associated with greater resistance of bacteria in skin samples at catheter removal. Severe CHGIS-associated contact dermatitis occurred in 8 patients (5.3 per 1000 catheters). Use of CHGIS dressings prevented 1 major CRI per 117 catheters. Catheter colonization rates were 142 of 1657 catheters (7.8%) in the 3-day group (10.4 per 1000 catheter-days) and 168 of 1828 catheters (8.6%) in the 7-day group (11.0 per 1000 catheter-days), a mean absolute difference of 0.8% (95% CI, -1.78% to 2.15%) (HR, 0.99; 95% CI, 0.77-1.28), indicating noninferiority of 7-day changes. The median number of dressing changes per catheter was 4 (IQR, 3-6) in the 3-day group and 3 (IQR, 2-5) in the 7-day group (P < .001).
Conclusions: Use of CHGIS dressings with intravascular catheters in the intensive care unit reduced risk of infection even when background infection rates were low. Reducing the frequency of changing unsoiled adherent dressings from every 3 days to every 7 days modestly reduces the total number of dressing changes and appears safe.
Trial registration: clinicaltrials.gov Identifier: NCT00417235.
Comment in
-
Preventing catheter-related bloodstream infections: thinking outside the checklist.JAMA. 2009 Mar 25;301(12):1285-7. doi: 10.1001/jama.2009.420. JAMA. 2009. PMID: 19318658 No abstract available.
-
Chlorhexidine-impregnated sponges and prevention of catheter-related infections.JAMA. 2009 Jul 22;302(4):379; author reply 380. doi: 10.1001/jama.2009.1035. JAMA. 2009. PMID: 19622810 No abstract available.
-
Chlorhexidine-impregnated sponges and prevention of catheter-related infections.JAMA. 2009 Jul 22;302(4):379; author reply 380. doi: 10.1001/jama.2009.1034. JAMA. 2009. PMID: 19622811 No abstract available.
-
Intravascular catheter dressings with chlorhexidine-impregnated sponges reduced infections in the ICU.Evid Based Nurs. 2009 Oct;12(4):115. doi: 10.1136/ebn.12.4.115. Evid Based Nurs. 2009. PMID: 19779082 No abstract available.
Similar articles
-
Randomized controlled trial of chlorhexidine dressing and highly adhesive dressing for preventing catheter-related infections in critically ill adults.Am J Respir Crit Care Med. 2012 Dec 15;186(12):1272-8. doi: 10.1164/rccm.201206-1038OC. Epub 2012 Oct 4. Am J Respir Crit Care Med. 2012. PMID: 23043083 Clinical Trial.
-
Comparison of Oligon catheters and chlorhexidine-impregnated sponges with standard multilumen central venous catheters for prevention of associated colonization and infections in intensive care unit patients: a multicenter, randomized, controlled study.Crit Care Med. 2012 Feb;40(2):420-9. doi: 10.1097/CCM.0b013e31822f0d4b. Crit Care Med. 2012. PMID: 21926583 Clinical Trial.
-
Economic evaluation of chlorhexidine-impregnated sponges for preventing catheter-related infections in critically ill adults in the Dressing Study.Crit Care Med. 2012 Jan;40(1):11-7. doi: 10.1097/CCM.0b013e31822f0604. Crit Care Med. 2012. PMID: 21926570 Clinical Trial.
-
Dressings and securement devices for central venous catheters (CVC).Cochrane Database Syst Rev. 2015 Sep 10;2015(9):CD010367. doi: 10.1002/14651858.CD010367.pub2. Cochrane Database Syst Rev. 2015. PMID: 26358142 Free PMC article. Review.
-
Use of chlorhexidine-impregnated dressing to prevent vascular and epidural catheter colonization and infection: a meta-analysis.J Antimicrob Chemother. 2006 Aug;58(2):281-7. doi: 10.1093/jac/dkl234. Epub 2006 Jun 6. J Antimicrob Chemother. 2006. PMID: 16757502 Review.
Cited by
-
Improving central venous catheter care with chlorhexidine gluconate dressings: evidence from a systematic review and Meta-analysis.J Health Popul Nutr. 2024 Nov 1;43(1):177. doi: 10.1186/s41043-024-00672-7. J Health Popul Nutr. 2024. PMID: 39487464 Free PMC article.
-
Surveillance and Prediction of Risk Factors for Central Line-Associated Bloodstream Infections in Saudi Arabia.Cureus. 2024 Jun 19;16(6):e62699. doi: 10.7759/cureus.62699. eCollection 2024 Jun. Cureus. 2024. PMID: 38903981 Free PMC article.
-
Dressings and securement devices to prevent complications for peripheral arterial catheters.Cochrane Database Syst Rev. 2024 May 23;5(5):CD013023. doi: 10.1002/14651858.CD013023.pub2. Cochrane Database Syst Rev. 2024. PMID: 38780138 Review.
-
Randomized controlled trial on healthy volunteers of pharmacokinetic and antimicrobial activity of a novel hydrogel-containing chlorhexidine dressing to prevent catheter-related bloodstream infection.Front Med (Lausanne). 2024 Jan 8;10:1335364. doi: 10.3389/fmed.2023.1335364. eCollection 2023. Front Med (Lausanne). 2024. PMID: 38259833 Free PMC article.
-
Significant Reduction in External Ventricular Drain-Related Infections After Introducing a Novel Bundle Protocol: A Before and After Trial.J Korean Med Sci. 2023 Dec 25;38(50):e386. doi: 10.3346/jkms.2023.38.e386. J Korean Med Sci. 2023. PMID: 38147836 Free PMC article.
Publication types
MeSH terms
Substances
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
