An epidemiologist's review of the case for pulsatile flow during cardiopulmonary bypass
- PMID: 19361038
- PMCID: PMC4680230
An epidemiologist's review of the case for pulsatile flow during cardiopulmonary bypass
Abstract
Not all science is created equally. New evidence is created daily, albeit of varying quality. Quality may be assessed on a number of fronts, although I approach my assessment of quality broadly. My earlier claim is not solely based on study design but on methodology and analytic approach. The foundational knowledge supporting pulsatile flow during cardiopulmonary bypass is not immune to this data quality. There are a number of articles supporting vs. discounting the use of pulsatile flow in this setting. However, there are inherent flaws in many of these. In this manuscript, I shall focus my attention on statistical power and sample size as it relates to the evidence base for pulsatile flow during cardiopulmonary bypass.
Similar articles
-
Quantification of pressure-flow waveforms and selection of components for the pulsatile extracorporeal circuit.J Extra Corpor Technol. 2009 Mar;41(1):P20-5. J Extra Corpor Technol. 2009. PMID: 19361036 Free PMC article. Review.
-
A randomized study of the influence of perfusion technique and pH management strategy in 316 patients undergoing coronary artery bypass surgery. I. Mortality and cardiovascular morbidity.J Thorac Cardiovasc Surg. 1995 Aug;110(2):340-8. doi: 10.1016/S0022-5223(95)70229-6. J Thorac Cardiovasc Surg. 1995. PMID: 7637351 Clinical Trial.
-
Pulsatile flow during cardiopulmonary bypass preserves postoperative microcirculatory perfusion irrespective of systemic hemodynamics.J Appl Physiol (1985). 2012 May;112(10):1727-34. doi: 10.1152/japplphysiol.01191.2011. Epub 2012 Mar 8. J Appl Physiol (1985). 2012. PMID: 22403352 Clinical Trial.
-
Pulsatile Versus Nonpulsatile Flow During Cardiopulmonary Bypass: Extent of Hemolysis and Clinical Significance.ASAIO J. 2020 Sep/Oct;66(9):1025-1030. doi: 10.1097/MAT.0000000000001154. ASAIO J. 2020. PMID: 32224786
-
Pulsatile perfusion during cardiopulmonary bypass procedures in neonates, infants, and small children.ASAIO J. 2007 Nov-Dec;53(6):706-9. doi: 10.1097/MAT.0b013e318158e3f9. ASAIO J. 2007. PMID: 18043152 Review.
References
-
- Alghamdi AA, Latter DA.. Pulsatile versus nonpulsatile cardiopulmonary bypass flow: An evidence-based approach. J Card Surg. 2006;21:347–54. - PubMed
-
- Ji B, Undar A.. An evaluation of the benefits of pulsatile versus non-pulsatile perfusion during cardiopulmonary bypass procedures in pediatric and adult cardiac patients. ASAIO J. 2006;52:357–61. - PubMed
-
- Wright G.. The assessment of pulsatile blood flow. Perfusion. 1995;10:135–40. - PubMed
-
- Taylor KM.. Pulsatile cardiopulmonary bypass. A review. J Cardiovasc Surg (Torino). 1981;22:561–8. - PubMed
-
- Canadian Task Force on Preventive Health Care. Available at: www.ctfphc.org Accessed June 15, 2008.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources