Imaging performance comparison between a LaBr3: Ce scintillator based and a CdTe semiconductor based photon counting compact gamma camera
Abstract
The authors report on the performance of two small field of view, compact gamma cameras working in single photon counting in planar imaging tests at 122 and 140 keV. The first camera is based on a LaBr3: Ce scintillator continuous crystal (49 x 49 x 5 mm3) assembled with a flat panel multianode photomultiplier tube with parallel readout. The second one belongs to the class of semiconductor hybrid pixel detectors, specifically, a CdTe pixel detector (14 x 14 x 1 mm3) with 256 x 256 square pixels and a pitch of 55 microm, read out by a CMOS single photon counting integrated circuit of the Medipix2 series. The scintillation camera was operated with selectable energy window while the CdTe camera was operated with a single low-energy detection threshold of about 20 keV, i.e., without energy discrimination. The detectors were coupled to pinhole or parallel-hole high-resolution collimators. The evaluation of their overall performance in basic imaging tasks is presented through measurements of their detection efficiency, intrinsic spatial resolution, noise, image SNR, and contrast recovery. The scintillation and CdTe cameras showed, respectively, detection efficiencies at 122 keV of 83% and 45%, intrinsic spatial resolutions of 0.9 mm and 75 microm, and total background noises of 40.5 and 1.6 cps. Imaging tests with high-resolution parallel-hole and pinhole collimators are also reported.
Similar articles
-
Evaluation of a CdTe semiconductor based compact γ camera for sentinel lymph node imaging.Med Phys. 2011 Mar;38(3):1547-60. doi: 10.1118/1.3555034. Med Phys. 2011. PMID: 21520866
-
CdTe compact gamma camera for coded aperture imaging in radioguided surgery.Phys Med. 2020 Jan;69:223-232. doi: 10.1016/j.ejmp.2019.12.024. Epub 2020 Jan 7. Phys Med. 2020. PMID: 31918374
-
Solid state detectors in nuclear medicine.Q J Nucl Med. 2002 Mar;46(1):3-7. Q J Nucl Med. 2002. PMID: 12072840 Review.
-
Silicon photomultiplier-based scintillation detectors for photon-counting CT: A feasibility study.Med Phys. 2021 Oct;48(10):6324-6338. doi: 10.1002/mp.14886. Epub 2021 Jun 25. Med Phys. 2021. PMID: 34169535 Free PMC article.
-
Wire chambers revisited.Eur J Nucl Med. 1993 Apr;20(4):348-58. doi: 10.1007/BF00169813. Eur J Nucl Med. 1993. PMID: 8491229 Review.
Cited by
-
Intraoperative Gamma Cameras: A Review of Development in the Last Decade and Future Outlook.J Imaging. 2023 May 16;9(5):102. doi: 10.3390/jimaging9050102. J Imaging. 2023. PMID: 37233321 Free PMC article. Review.
-
Above and Beyond Robotic Surgery and 3D Modelling in Paediatric Cancer Surgery.Front Pediatr. 2021 Dec 20;9:777840. doi: 10.3389/fped.2021.777840. eCollection 2021. Front Pediatr. 2021. PMID: 34988038 Free PMC article. Review.
-
Cadmium Telluride Semiconductor Detector for Improved Spatial and Energy Resolution Radioisotopic Imaging.World J Nucl Med. 2017 Apr-Jun;16(2):101-107. doi: 10.4103/1450-1147.203079. World J Nucl Med. 2017. PMID: 28553175 Free PMC article. Review.
-
SPECT detectors: the Anger Camera and beyond.Phys Med Biol. 2011 Sep 7;56(17):R145-82. doi: 10.1088/0031-9155/56/17/R01. Epub 2011 Aug 9. Phys Med Biol. 2011. PMID: 21828904 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources