[Internal quality control of the blood products in the Lomé National Blood Transfusion Centre]

Tunis Med. 2008 Jul;86(7):698-703.
[Article in French]

Abstract

Aim: Evaluate the conformity of blood red cells units prepared in the Lomé CNTS with European norms concerning volume, haemoglobin content and haematocrite. Measure the conservation of the haemostatic properties and the rate of haemostasis factors V and VIII in the fresh frozen plasma. Measure the rate of residual cells in the plasma.

Methods: In the year 2006, from March 1st to April 15th, we analysed the quality of 135 units of whole blood, red blood cells (RBC) and plasma from blood donors in the Lomé National Blood Transfusion Centre. The quality control had concerned: the volume of whole blood units; the volume, the haemoglobin content and the haematocrite of red blood cells units; the volume, the prothrombin rate, the cephalin with activator time (TCA), the rate of haemostasis factors V and VIII and the number of residual cells (red cells, leucocytes and platelets) in the plasma.

Results: Among the 135 units of whole blood which were controlled, 50.57% were in conformity with the norms concerning the volume. The red blood cells units were in conformity with norms concerning their volume, their haemoglobin content and their haematocrite respectively in 21.48%, 80.75% and 20% of the cases. The volume of 75.56% of the plasma units controlled were conform with the norm. All of the plasma units were conform with the norm concerning the number of residual platelets while the number of residual red blood cells and leucocytes were conform respectively in 80.74% and 60%. The percentage of conformity concerning the prothrombin rate, the TCA, the coagulation factor V and the factor VIII were respectively 66.67; 97.78; 48.89 and 47.4 before freezing, and 54.81; 88.14; 64.44; 84.44 a month after freezing.

Conclusion: To improve the quality of the new blood products of the Lomé CNTS, some correctives actions must be applied concerning the adequate volume of blood which must be collected from the donors, the position of the blood bags in during the centrifugation and the volume of plasma which must be take out of the bag of red cells.

Publication types

  • English Abstract

MeSH terms

  • Blood Transfusion*
  • Humans
  • Laboratories / standards*
  • Prospective Studies
  • Quality Control
  • Togo