Frequency of failure to inform patients of clinically significant outpatient test results
- PMID: 19546413
- DOI: 10.1001/archinternmed.2009.130
Frequency of failure to inform patients of clinically significant outpatient test results
Erratum in
- Arch Intern Med. 2009 Sep 28;169(17):1626
Abstract
Background: Failing to inform a patient of an abnormal outpatient test result can be a serious error, but little is known about the frequency of such errors or the processes for managing results that may reduce errors.
Methods: We conducted a retrospective medical record review of 5434 randomly selected patients aged 50 to 69 years in 19 community-based and 4 academic medical center primary care practices. Primary care practice physicians were surveyed about their processes for managing test results, and individual physicians were notified of apparent failures to inform and asked whether they had informed the patient. Blinded reviewers calculated a "process score" ranging from 0 to 5 for each practice using survey responses.
Results: The rate of apparent failures to inform or to document informing the patient was 7.1% (135 failures divided by 1889 abnormal results), with a range of 0% to 26.2%. The mean process score was 3.8 (range, 0.9-5.0). In mixed-effects logistic regression, higher process scores were associated with lower failure rates (odds ratio, 0.68; P < .001). Use of a "partial electronic medical record" (paper-based progress notes and electronic test results or vice versa) was associated with higher failure rates compared with not having an electronic medical record (odds ratio, 1.92; P = .03) or with having an electronic medical record that included both progress notes and test results (odds ratio, 2.37; P = .007).
Conclusions: Failures to inform patients or to document informing patients of abnormal outpatient test results are common; use of simple processes for managing results is associated with lower failure rates.
Comment in
-
EMRs do not improve reporting rates of abnormal laboratory results?Arch Intern Med. 2009 Oct 26;169(19):1815-6; author reply 1816-7. doi: 10.1001/archinternmed.2009.368. Arch Intern Med. 2009. PMID: 19858447 No abstract available.
-
Informatics aids to reduce failure rates in notification of abnormal outpatient test results.Arch Intern Med. 2009 Oct 26;169(19):1815; author reply 1816-7. doi: 10.1001/archinternmed.2009.367. Arch Intern Med. 2009. PMID: 19858448 No abstract available.
-
Giving patients their results online might be the answer.Arch Intern Med. 2009 Oct 26;169(19):1816; author reply 1816-7. doi: 10.1001/archinternmed.2009.369. Arch Intern Med. 2009. PMID: 19858449 No abstract available.
Similar articles
-
Mitigation of patient harm from testing errors in family medicine offices: a report from the American Academy of Family Physicians National Research Network.Qual Saf Health Care. 2008 Jun;17(3):201-8. doi: 10.1136/qshc.2007.022566. Qual Saf Health Care. 2008. PMID: 18519627
-
Documentation and coding of ED patient encounters: an evaluation of the accuracy of an electronic medical record.Am J Emerg Med. 2006 Oct;24(6):664-78. doi: 10.1016/j.ajem.2006.02.005. Am J Emerg Med. 2006. PMID: 16984834
-
Informatics aids to reduce failure rates in notification of abnormal outpatient test results.Arch Intern Med. 2009 Oct 26;169(19):1815; author reply 1816-7. doi: 10.1001/archinternmed.2009.367. Arch Intern Med. 2009. PMID: 19858448 No abstract available.
-
The brain-to-brain loop concept for laboratory testing 40 years after its introduction.Am J Clin Pathol. 2011 Dec;136(6):829-33. doi: 10.1309/AJCPR28HWHSSDNON. Am J Clin Pathol. 2011. PMID: 22095366 Review.
-
Analytical interferences and analytical quality.Clin Chim Acta. 2009 Jun;404(1):37-40. doi: 10.1016/j.cca.2009.03.031. Epub 2009 Mar 21. Clin Chim Acta. 2009. PMID: 19306857 Review.
Cited by
-
The Nature, Causes, and Clinical Impact of Errors in the Clinical Laboratory Testing Process Leading to Diagnostic Error: A Voluntary Incident Report Analysis.J Patient Saf. 2023 Dec 1;19(8):573-579. doi: 10.1097/PTS.0000000000001166. Epub 2023 Sep 28. J Patient Saf. 2023. PMID: 37796227 Free PMC article.
-
A dual-binding magnetic immunoassay to predict spontaneous preterm birth.Front Bioeng Biotechnol. 2023 Sep 13;11:1256267. doi: 10.3389/fbioe.2023.1256267. eCollection 2023. Front Bioeng Biotechnol. 2023. PMID: 37790251 Free PMC article.
-
Study of patients' attitude to automatic interpretation of laboratory test results and its influence on follow-up rate.BMC Med Inform Decis Mak. 2022 Mar 27;22(1):79. doi: 10.1186/s12911-022-01805-w. BMC Med Inform Decis Mak. 2022. PMID: 35346173 Free PMC article.
-
Informed or anxious: patient preferences for release of test results of increasing sensitivity on electronic patient portals.Health Technol (Berl). 2022;12(1):59-67. doi: 10.1007/s12553-021-00628-5. Epub 2022 Jan 8. Health Technol (Berl). 2022. PMID: 35036280 Free PMC article.
-
Delayed or failure to follow-up abnormal breast cancer screening mammograms in primary care: a systematic review.BMC Cancer. 2021 Apr 7;21(1):373. doi: 10.1186/s12885-021-08100-3. BMC Cancer. 2021. PMID: 33827476 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
