Abstract
Context: Prolongation of the electrocardiographic PR interval, known as first-degree atrioventricular block when the PR interval exceeds 200 milliseconds, is frequently encountered in clinical practice.
Objective: To determine the clinical significance of PR prolongation in ambulatory individuals.
Design, setting, and participants: Prospective, community-based cohort including 7575 individuals from the Framingham Heart Study (mean age, 47 years; 54% women) who underwent routine 12-lead electrocardiography. The study cohort underwent prospective follow-up through 2007 from baseline examinations in 1968-1974. Multivariable-adjusted Cox proportional hazards models were used to examine the associations of PR interval with the incidence of arrhythmic events and death.
Main outcome measures: Incident atrial fibrillation (AF), pacemaker implantation, and all-cause mortality.
Results: During follow-up, 481 participants developed AF, 124 required pacemaker implantation, and 1739 died. At the baseline examination, 124 individuals had PR intervals longer than 200 milliseconds. For those with PR intervals longer than 200 milliseconds compared with those with PR intervals of 200 milliseconds or shorter, incidence rates per 10 000 person-years were 140 (95% confidence interval [CI], 95-208) vs 36 (95% CI, 32-39) for AF, 59 (95% CI, 40-87) vs 6 (95% CI, 5-7) for pacemaker implantation, and 334 (95% CI, 260-428) vs 129 (95% CI, 123-135) for all-cause mortality. Corresponding absolute risk increases were 1.04% (AF), 0.53% (pacemaker implantation), and 2.05% (all-cause mortality) per year. In multivariable analyses, each 20-millisecond increment in PR was associated with an adjusted hazard ratio (HR) of 1.11 (95% CI, 1.02-1.22; P = .02) for AF, 1.22 (95% CI, 1.14-1.30; P < .001) for pacemaker implantation, and 1.08 (95% CI, 1.02-1.13; P = .005) for all-cause mortality. Individuals with first-degree atrioventricular block had a 2-fold adjusted risk of AF (HR, 2.06; 95% CI, 1.36-3.12; P < .001), 3-fold adjusted risk of pacemaker implantation (HR, 2.89; 95% CI, 1.83-4.57; P < .001), and 1.4-fold adjusted risk of all-cause mortality (HR, 1.44, 95% CI, 1.09-1.91; P = .01).
Conclusion: Prolongation of the PR interval is associated with increased risks of AF, pacemaker implantation, and all-cause mortality.
Figures
Comment in
-
Outcomes in patients with prolonged PR interval or first-degree atrioventricular block.JAMA. 2009 Nov 11;302(18):1967; author reply 1967-8. doi: 10.1001/jama.2009.1604. JAMA. 2009. PMID: 19903912 No abstract available.
-
Outcomes in patients with prolonged PR interval or first-degree atrioventricular block.JAMA. 2009 Nov 11;302(18):1967; author reply 1967-8. doi: 10.1001/jama.2009.1603. JAMA. 2009. PMID: 19903913 No abstract available.
-
ACP Journal Club: Prolonged PR intervals were associated with increased risk for atrial fibrillation, pacemaker implantation, and mortality.Ann Intern Med. 2009 Nov 17;151(10):JC5-13. doi: 10.7326/0003-4819-151-10-200911170-02013. Ann Intern Med. 2009. PMID: 19920258 No abstract available.
Similar articles
-
Effect of PR interval and pacing mode on persistent atrial fibrillation incidence in dual chamber pacemaker patients: a sub-study of the international randomized MINERVA trial.Europace. 2019 Apr 1;21(4):636-644. doi: 10.1093/europace/euy286. Europace. 2019. PMID: 30649270 Clinical Trial.
-
Electrocardiographic PR interval and adverse outcomes in older adults: the Health, Aging, and Body Composition study.Circ Arrhythm Electrophysiol. 2013 Feb;6(1):84-90. doi: 10.1161/CIRCEP.112.975342. Epub 2012 Dec 16. Circ Arrhythm Electrophysiol. 2013. PMID: 23243193 Free PMC article.
-
Association of cardiac implantable electronic devices with survival in bifascicular block and prolonged PR interval on electrocardiogram.J Interv Card Electrophysiol. 2018 Aug;52(3):335-341. doi: 10.1007/s10840-018-0389-0. Epub 2018 Jun 16. J Interv Card Electrophysiol. 2018. PMID: 29907894
-
Prolonged PR interval, first-degree heart block and adverse cardiovascular outcomes: a systematic review and meta-analysis.Heart. 2016 May;102(9):672-80. doi: 10.1136/heartjnl-2015-308956. Epub 2016 Feb 15. Heart. 2016. PMID: 26879241 Review.
-
PR prolongation as a predictor of atrial fibrillation onset: A state-of-the-art review.Curr Probl Cardiol. 2024 Apr;49(4):102469. doi: 10.1016/j.cpcardiol.2024.102469. Epub 2024 Feb 16. Curr Probl Cardiol. 2024. PMID: 38369207 Review.
Cited by
-
Increased interleukin-6 levels are associated with atrioventricular conduction delay in severe COVID-19 patients.J Arrhythm. 2024 Jul 31;40(5):1137-1148. doi: 10.1002/joa3.13114. eCollection 2024 Oct. J Arrhythm. 2024. PMID: 39416238 Free PMC article.
-
Electrocardiogram changes post surgical repair of tetralogy of Fallot with valve-sparing versus transannular patch: A retrospective observational study.Glob Cardiol Sci Pract. 2024 Aug 1;2024(4):e202428. doi: 10.21542/gcsp.2024.28. eCollection 2024 Aug 1. Glob Cardiol Sci Pract. 2024. PMID: 39351470 Free PMC article.
-
The Atrioventricular Coupling in Heart Failure: Pathophysiological and Therapeutic Aspects.Rev Cardiovasc Med. 2024 May 14;25(5):169. doi: 10.31083/j.rcm2505169. eCollection 2024 May. Rev Cardiovasc Med. 2024. PMID: 39076484 Free PMC article. Review.
-
Gene Polymorphism and Recurrent Atrial Fibrillation after Catheter Ablation: A Comprehensive Review.Rev Cardiovasc Med. 2023 Apr 18;24(4):119. doi: 10.31083/j.rcm2404119. eCollection 2023 Apr. Rev Cardiovasc Med. 2023. PMID: 39076272 Free PMC article. Review.
-
Artificial Intelligence-Enabled Electrocardiography Predicts Future Pacemaker Implantation and Adverse Cardiovascular Events.J Med Syst. 2024 Jul 19;48(1):67. doi: 10.1007/s10916-024-02088-6. J Med Syst. 2024. PMID: 39028354
References
-
- Packard JM, Graettinger JS, Graybiel A. Analysis of the electrocardiograms obtained from 1000 young healthy aviators; ten year follow-up. Circulation. 1954;10:384–400. - PubMed
-
- Blackburn H, Taylor HL, Keys A. Coronary heart disease in seven countries. XVI. The electrocardiogram in prediction of five-year coronary heart disease incidence among men aged forty through fifty-nine. Circulation. 1970;41:I154–I161. - PubMed
-
- Erikssen J, Otterstad JE. Natural course of a prolonged PR interval and the relation between PR and incidence of coronary heart disease. A 7-year follow-up study of 1832 apparently healthy men aged 40–59 years. Clin Cardiol. 1984;7:6–13. - PubMed
-
- Schwartzman D. Atrioventricular block and atrioventricular dissociation. In: Zipes D, Jalife J, editors. Cardiac Electrophysiology: From Cell to Bedside. 4th ed. Philadelphia, PA: Saunders; 2004. pp. 485–489.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials