In vivo dynamic deformation of the mitral valve annulus

Ann Biomed Eng. 2009 Sep;37(9):1757-71. doi: 10.1007/s10439-009-9749-3. Epub 2009 Jul 8.

Abstract

Though mitral valve (MV) repair surgical procedures have increased in the United States [Gammie, J. S., et al. Ann. Thorac. Surg. 87(5):1431-1437, 2009; Nowicki, E. R., et al. Am. Heart J. 145(6):1058-1062, 2003], studies suggest that altering MV stress states may have an effect on tissue homeostasis, which could impact the long-term outcome [Accola, K. D., et al. Ann. Thorac. Surg. 79(4):1276-1283, 2005; Fasol, R., et al. Ann. Thorac. Surg. 77(6):1985-1988, 2004; Flameng, W., P. Herijgers, and K. Bogaerts. Circulation 107(12):1609-1613, 2003; Gillinov, A. M., et al. Ann. Thorac. Surg. 69(3):717-721, 2000]. Improved computational modeling that incorporates structural and geometrical data as well as cellular components has the potential to predict such changes; however, the absence of important boundary condition information limits current efforts. In this study, novel high definition in vivo annular kinematic data collected from surgically implanted sonocrystals in sheep was fit to a contiguous 3D spline based on quintic-order hermite shape functions with C(2) continuity. From the interpolated displacements, the annular axial strain and strain rate, bending, and twist along the entire annulus were calculated over the cardiac cycle. Axial strain was shown to be regionally and temporally variant with minimum and maximum values of -10 and 4%, respectively, observed. Similarly, regionally and temporally variant strain rate values, up to 100%/s contraction and 120%/s elongation, were observed. Both annular bend and twist data showed little deviation from unity with limited regional variations, indicating that most of the energy for deformation was associated with annular axial strain. The regionally and temporally variant strain/strain rate behavior of the annulus are related to the varied fibrous-muscle structure and contractile behavior of the annulus and surrounding ventricular structures, although specific details are still unavailable. With the high resolution shape and displacement information described in this work, high fidelity boundary conditions can be prescribed in future MV finite element models, leading to new insights into MV function and strategies for repair.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Heart Ventricles
  • Male
  • Mitral Valve / physiology*
  • Models, Cardiovascular*
  • Myocardial Contraction / physiology*
  • Sheep
  • Ventricular Function / physiology