Comparison of point of care and laboratory HbA1c analysis: a MetroNet study
- PMID: 19587262
- DOI: 10.3122/jabfm.2009.04.090057
Comparison of point of care and laboratory HbA1c analysis: a MetroNet study
Abstract
Background: Evaluating new technology in clinical practice is an important component of translating research into practice. We considered the feasibility of using a Clinical Laboratory Improvement Amendments (CLIA)-waived point of care (POC) glycohemoglobin (HbA1c) methodology in busy family medicine centers by comparing the results of POC HbA1c and laboratory analysis results.
Methods: Recruited from 5 MetroNet practices, the participants were adult diabetic patients having blood samples drawn for laboratory analysis of HbA1c. Each agreed to provide a capillary blood sample for POC testing.
Results: With data on 99 paired samples, the POC method yielded a mean HbA1c of 7.38%, which was equivalent to the mean of 7.53% produced with all combined standard laboratory analyses. The Pearson correlation between POC and the laboratory analysis test results was 0.884 (P < .001). POC test sensitivity was 81.8% and specificity was 93.2%. Eighteen percent of patients with an HbA1c > = 7% by laboratory analysis were not identified as such by the POC test.
Conclusions: Before adopting a POC methodology, practices are encouraged to review its feasibility in the context of the office routine, and also to conduct periodic comparisons of the accuracy of POC test results compared with those from laboratory analysis.
Similar articles
-
Correlation of same-visit HbA1c test with laboratory-based measurements: a MetroNet study.BMC Fam Pract. 2005 Jul 13;6:28. doi: 10.1186/1471-2296-6-28. BMC Fam Pract. 2005. PMID: 16014170 Free PMC article.
-
Accuracy and Precision of a Point-of-Care HbA1c Test.J Diabetes Sci Technol. 2020 Sep;14(5):883-889. doi: 10.1177/1932296819831292. Epub 2019 Mar 10. J Diabetes Sci Technol. 2020. PMID: 30854894 Free PMC article.
-
Point-of-care glucose and hemoglobin A1c in emergency department patients without known diabetes: implications for opportunistic screening.Acad Emerg Med. 2008 Dec;15(12):1241-7. doi: 10.1111/j.1553-2712.2008.00240.x. Epub 2008 Sep 8. Acad Emerg Med. 2008. PMID: 18785943
-
Point-of-Care Hemoglobin A1c Testing: An Evidence-Based Analysis.Ont Health Technol Assess Ser. 2014 Jul 1;14(8):1-30. eCollection 2014. Ont Health Technol Assess Ser. 2014. PMID: 26316922 Free PMC article. Review.
-
Performance of point-of-care HbA1c test devices: implications for use in clinical practice - a systematic review and meta-analysis.Clin Chem Lab Med. 2017 Feb 1;55(2):167-180. doi: 10.1515/cclm-2016-0303. Clin Chem Lab Med. 2017. PMID: 27658148 Review.
Cited by
-
Which Point-of-Care Tests Would Be Most Beneficial to Add to Clinical Practice?: Findings From a Survey of 3 Family Medicine Clinics in the United States.Point Care. 2017 Dec;16(4):168-172. doi: 10.1097/POC.0000000000000151. Epub 2017 Nov 14. Point Care. 2017. PMID: 29333106 Free PMC article.
-
Impact of HbA1c Testing at Point of Care on Diabetes Management.J Diabetes Sci Technol. 2017 May;11(3):611-617. doi: 10.1177/1932296816678263. Epub 2016 Nov 27. J Diabetes Sci Technol. 2017. PMID: 27898388 Free PMC article. Review.
-
Team Science Approach to Developing Consensus on Research Good Practices for Practice-Based Research Networks: A Case Study.Clin Transl Sci. 2015 Dec;8(6):632-7. doi: 10.1111/cts.12363. Epub 2015 Nov 25. Clin Transl Sci. 2015. PMID: 26602516 Free PMC article.
-
Effect of the different assays of HbA1c on diabetic patients monitoring.J Diabetes Metab Disord. 2015 Aug 4;14:65. doi: 10.1186/s40200-015-0193-7. eCollection 2015. J Diabetes Metab Disord. 2015. PMID: 26244134 Free PMC article.
-
Diagnostic point-of-care tests in resource-limited settings.Lancet Infect Dis. 2014 Mar;14(3):239-49. doi: 10.1016/S1473-3099(13)70250-0. Epub 2013 Dec 10. Lancet Infect Dis. 2014. PMID: 24332389 Free PMC article. Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical