Patient misidentification in Papanicolaou tests: a systems-based approach to reducing errors
- PMID: 19653729
- DOI: 10.5858/133.8.1297
Patient misidentification in Papanicolaou tests: a systems-based approach to reducing errors
Abstract
Context: Patient safety is of prime concern in every laboratory. Double labeling of glass slides is performed in many cytology laboratories where handwritten patient information on the frosted portion of the glass is overlaid with paper labels (sometimes containing bar codes). The cytotechnologists match this information by turning slides over. We use SurePath liquid-based cytology for Papanicolaou tests in our laboratory and noticed patient misidentification because of slide labeling errors, a problem that has not been addressed in the literature.
Objective: To reduce slide labeling errors without increasing costs, using a systems-based approach.
Design: All errors from mislabeled slides during November 2006 were documented, and an informal root-cause analysis was performed. Slides were labeled on opposite ends and monitored for errors.
Results: Labeling on different ends of the glass slide reduced our error rate from 0.59% to 0%, made visual matching easy, and did not alter costs.
Conclusions: The practice of overlaying handwritten information with printed labels for liquid-based Papanicolaou tests should be strongly discouraged and replaced with placing patient information in separate portions of the glass slide so that crucial patient identification is not hidden and visual matching is easy.
Similar articles
-
Identification errors in pathology and laboratory medicine.Clin Lab Med. 2004 Dec;24(4):979-96, vii. doi: 10.1016/j.cll.2004.05.013. Clin Lab Med. 2004. PMID: 15555752 Review.
-
Technical external quality assessment for SurePath stained liquid-based cytology gynaecological cervical samples using control material--a novel approach.Cytopathology. 2009 Jun;20(3):169-75. doi: 10.1111/j.1365-2303.2007.00553.x. Epub 2008 Jul 14. Cytopathology. 2009. PMID: 18637809
-
Mislabeling of cases, specimens, blocks, and slides: a college of american pathologists study of 136 institutions.Arch Pathol Lab Med. 2011 Aug;135(8):969-74. doi: 10.5858/2010-0726-CPR. Arch Pathol Lab Med. 2011. PMID: 21809987
-
Specimen labeling errors in surgical pathology: an 18-month experience.Am J Clin Pathol. 2010 Sep;134(3):466-70. doi: 10.1309/AJCPHLQHJ0S3DFJK. Am J Clin Pathol. 2010. PMID: 20716804
-
Causes, consequences, detection, and prevention of identification errors in laboratory diagnostics.Clin Chem Lab Med. 2009;47(2):143-53. doi: 10.1515/CCLM.2009.045. Clin Chem Lab Med. 2009. PMID: 19099525 Review.
Cited by
-
How often are Patients Harmed When They Visit the Computed Tomography Suite? A Multi-year Experience, in Incident Reporting, in a Large Academic Medical Center.Eur Radiol. 2016 Jul;26(7):2064-72. doi: 10.1007/s00330-015-4061-0. Epub 2015 Nov 11. Eur Radiol. 2016. PMID: 26560719
MeSH terms
LinkOut - more resources
Full Text Sources
Medical