Purpose: Dosimetric data are reported for five cases of radiation-induced myelopathy after stereotactic body radiotherapy (SBRT) to spinal tumors. Analysis per the biologically effective dose (BED) model was performed.

Methods and materials: Five patients with radiation myelopathy were compared to a subset of 19 patients with no radiation myelopathy post-SBRT. In all patients, the thecal sac was contoured to represent the spinal cord, and doses to the maximum point, 0.1-, 1-, 2-, and 5-cc volumes, were analyzed. The mean normalized 2-Gy-equivalent BEDs (nBEDs), calculated using an alpha/beta value of 2 for late toxicity with units Gy 2/2, were compared using the t test and analysis of variance test.

Results: Radiation myelopathy was observed at the maximum point with doses of 25.6 Gy in two fractions, 30.9 Gy in three fractions, and 14.8, 13.1, and 10.6 Gy in one fraction. Overall, there was a significant interaction between patient subsets and volume based on the nBED (p = 0.0003). Given individual volumes, a significant difference was observed for the mean maximum point nBED (p = 0.01).

Conclusions: The maximum point dose should be respected for spine SBRT. For single-fraction SBRT 10 Gy to a maximum point is safe, and up to five fractions an nBED of 30 to 35 Gy 2/2 to the thecal sac also poses a low risk of radiation myelopathy.

MeSH terms

  • Adult
  • Analysis of Variance
  • Female
  • Humans
  • Maximum Tolerated Dose*
  • Middle Aged
  • Radiation Injuries / etiology*
  • Radiosurgery / adverse effects*
  • Radiosurgery / methods
  • Relative Biological Effectiveness
  • Retrospective Studies
  • Spinal Cord / radiation effects*
  • Spinal Cord Diseases / etiology*
  • Spinal Cord Neoplasms / surgery